Magnetic resonance-compatible-spirometry: principle, technical evaluation and application.
نویسندگان
چکیده
The aim of this study was to assess the feasibility and accuracy of a novel magnetic resonance-compatible (MRc)-spirometer. The influence of body posture, magnetic resonance (MR)-setting and image acquisition on lung function was evaluated. Dynamic MR imaging (dMRI) was compared with simultaneously measured lung function. The development of the MRc-spirometer was based on a commercial spirometer and evaluated by flow-generator measurements and forced expiratory manoeuvres in 34 healthy nonsmokers (17 females and 17 males, mean age 32.9 yrs). Mean differences between forced expiratory volume in one second (FEV(1)) and forced vital capacity (FVC) were calculated and a sample paired t-test and Bland-Altman plots were generated. A total of 11 subjects underwent different subsequent MRc-spirometric measurements to assess the influence of the components of the MR system on lung function. The mean (95% confidence interval) difference of FEV(1) and FVC between the two systems was 0.004 (-0.04-0.04) L and 0.018 (-0.05-0.09) L, respectively. In the subgroup analysis, an influence of the MR-system on FEV(1) was found. FEV(1) correlated well with the dMRI measurement of the apico-diaphragmatic distance-change after the first second of forced expiration (r = 0.72). In conclusion, magnetic resonance-compatible-spirometry is feasible, reliable and safe. The magnetic resonance-setting only has a small influence on simultaneously measured forced expiratory volume in one second. Dynamic magnetic resonance imaging measurements correlate well with simultaneously acquired lung function parameters.
منابع مشابه
Application of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period
To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...
متن کاملGeometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes
Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...
متن کاملUse of Magnetic Resonance Imaging in Food Quality Control: A Review
Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...
متن کاملMagnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study.
The continuous technological progress of magnetic resonance imaging (MRI), as well as its widespread clinical use as a highly sensitive tool in diagnostics and advanced brain research, has brought a high demand for the development of magnetic resonance (MR)-compatible robotic/mechatronic systems. Revolutionary robots guided by real-time three-dimensional (3-D)-MRI allow reliable and precise min...
متن کاملThermal Convection in a (Kuvshiniski-type) Viscoelastic Rotating Fluid in the Presence of Magnetic Field through Porous Medium (TECHNICAL NOTE)
The effect of magnetic field on an incompressible (Kuvshiniski-Type) viscoelastic rotating fluid heated from below in porous medium is considered. For the case of stationary convection, magnetic field and medium permeability have both stabilizing and destabilizing effect on the thermal convection under some conditions whereas rotation has a stabilizing effect on the thermal convection. In the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 30 5 شماره
صفحات -
تاریخ انتشار 2007