Do blood contamination and haemostatic agents affect microtensile bond strength of dual cured resin cement to dentin?
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to evaluate the effects of blood contamination and haemostatic agents such as Ankaferd Blood Stopper (ABS) and hydrogen peroxide (H2O2) on the microtensile bond strength between dual cured resin cement-dentin interface. MATERIAL AND METHODS Twelve pressed lithium disilicate glass ceramics were luted to flat occlusal dentin surfaces with Panavia F under the following conditions: CONTROL GROUP no contamination, Group Blood: blood contamination, Group ABS: ABS contamination Group H2O2: H2O2 contamination. The specimens were sectioned to the beams and microtensile testing was carried out. Failure modes were classified under stereomicroscope. Two specimens were randomly selected from each group, and SEM analyses were performed. RESULTS There were significant differences in microtensile bond strengths (µTBS) between the control and blood-contaminated groups (p<0.05), whereas there were no significant differences found between the control and the other groups (p>0.05). CONCLUSIONS Contamination by blood of dentin surface prior to bonding reduced the bond strength between resin cement and the dentin. Ankaferd Blood Stoper and H2O2 could be used safely as blood stopping agents during cementation of all-ceramics to dentin to prevent bond failure due to blood contamination.
منابع مشابه
Evaluation of bond strength between leucite-based and lithium disilicate-based ceramics to dentin after cementation with conventional and self-adhesive resin agents.
The aim of this study was to compare the microtensile bond strength of two heat-pressed ceramics (leucite-based--IPS Empress Esthetic/Ivoclar Vivadent, and lithium disilicate-based --IPS e.max Press/Ivoclar Vivadent) to dentin with the use of conventional and self-adhesive resin cements. The occlusal surface of 60 intact human molars was removed and the dentin was exposed. Ceramic blocks were c...
متن کاملEffects of cement-curing mode and light-curing unit on the bond durability of ceramic cemented to dentin.
The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability of a feldspathic ceramic bonded to dentin. The crowns of 40 human molars were sectioned, exposing the dentin. Forty ceramic blocks of VITA VM7 were produced according to the manufacturer's recommendations. The ceramic surface was etched with 10% hydrofluoric aci...
متن کاملEffect of saliva and blood contamination on shear bond strength of cured dentin adhesives
Effect of saliva and blood contamination on shear bond strength of cured dentin adhesives Dr. E. Yassini* - Dr. E. Shidoush** *- Professor of Operative Dentistry Dept. - Faculty of Dentistry - Tehran University of Medical Sciences. ** - Dentist. Background and Aim: Achieving good moisture control is a common problem encountered in restorative dentistry, especially after applying and curing dent...
متن کاملThe effect of dentin desensitizers and Nd:YAG laser pre-treatment on microtensile bond strength of self-adhesive resin cement to dentin
PURPOSE The purpose of this study is to evaluate if pre-treatment with desensitizers have a negative effect on microtensile bond strength before cementing a restoration using recently introduced self-adhesive resin cement to dentin. MATERIALS AND METHODS Thirty-five human molars' occlusal surfaces were ground to expose dentin; and were randomly grouped as (n=5); 1) Gluma-(Glutaraldehyde/HEMA)...
متن کاملMicrotensile bond strength of a newly developed resin cement to dentin.
The purpose of this study was to evaluate the microtensile bond strength (µTBS) of a newly developed resin cement, ECD-89 (ECD, Tokuyama Dental, Tokyo, Japan) to dentin and to observe the interfacial micromorphology by comparing with two commercial resin cements, Multilink Automix (MA, Ivoclar Vivadent AG, Schaan, Liechtenstein) and Panavia F2.0 (PF, Kuraray Noritake Dental, Tokyo, Japan). Flat...
متن کامل