Comparison of 10 hemostatic dressings in a groin puncture model in swine.
نویسندگان
چکیده
BACKGROUND The use of mineral (clay) or biologic (chitosan) materials has improved the efficacy of dressings used in the bleeding control of noncompressible areas. A series of novel manufactured products already evaluated in a vascular transection model was further compared in a severe vascular puncture injury model. METHODS Ten hemostatic dressings were tested in anesthetized Yorkshire swine hemorrhaged for 45 seconds in a femoral arterial puncture model. Application of these dressings was followed by 5 minutes of compression (about 175 mm Hg), and at 15 minutes, 500 mL resuscitation fluid (Hextand) was infused during a 30-minute period. The animals were monitored for a 3-hour experimental observation period. Primary outcomes were incidence of bleeding after dressing application and animal survival. RESULTS Blood loss was 18.8% +/- 5.2% estimated blood volume (EBV) after 45 seconds of free bleeding. Relative performance of dressings is characterized as groups of dressings that performed similarly. Recurrence of bleeding after application was observed with most dressings and was lower with Woundstat, Celox, X-Sponge, and ACS+ (35% +/- 49%) compared with FP-21, Hemcon, Chitoflex, and Bloodstop (79% +/- 43%; P < .01). Blood loss after treatment was 25.3% +/- 18.4% EBV for the top four dressings and 53.0% +/- 18.4% EBV for the bottom four (P < .05). Survival was higher for top four vs bottom four dressings (78% +/- 12% vs 25% +/- 0%, respectively; P < .01). Overall performance of these dressings according to survival, incidence of bleeding, and post-treatment blood loss, yielded similar ranking as with a previously tested transection injury model. CONCLUSIONS The findings indicated that the efficacy of Woundstat, Celox, X-Sponge, and ACS+ were similar and superior in improving survival, hemostasis, and maintenance of mean arterial pressure in an actively bleeding wound caused in this severe vascular injury model.
منابع مشابه
Determination of efficacy of a novel alginate dressing in a lethal arterial injury model in swine.
INTRODUCTION Alginate is a biocompatible polysaccharide that is commonly used in the pharmaceutical, biomedical, cosmetic, and food industries. Though solid dressings composed of alginate can absorb water and promote wound healing, they are not effective hemostatic materials, particularly against massive hemorrhage. The purpose of this study is to attempt to increase the hemostatic capabilities...
متن کاملDetermination of efficacy of novel modified chitosan sponge dressing in a lethal arterial injury model in swine.
BACKGROUND Chitosan is a functional biopolymer that has been widely used as a hemostat. Recently, its efficacy has been questioned due to clinical failures as a result of poor adhesiveness. The purpose of this study was to compare, in a severe groin injury model in swine, the hemostatic properties of an unmodified standard chitosan sponge with standard gauze dressing and a novel hydrophobically...
متن کاملComparison of Combat Gauze and TraumaStat in two severe groin injury models.
BACKGROUND Fabric-like hemostatic dressings offer promise for hemorrhage control in noncompressible areas, especially given their similarity in form to standard gauze currently in use. Recently, two such products, Combat Gauze (CBG) and TraumaStat (TMS), were introduced. Their performance is evaluated in two vascular injury models. MATERIALS AND METHODS The dressings were evaluated in anesthe...
متن کاملA novel highly porous silica and chitosan-based hemostatic dressing is superior to HemCon and gauze sponges.
BACKGROUND Hemostatic dressings have become increasingly popular as the optimal initial treatment for severe hemorrhage. The purpose of this study was to compare the hemostatic properties of a novel highly porous silica and chitosan-based dressing (TraumaStat) to HemCon, and gauze dressing in a severe groin injury model in swine. METHODS Thirty swine were blindly randomized to receive TraumaS...
متن کاملChitosan based advanced hemostatic dressing is associated with decreased blood loss in a swine uncontrolled hemorrhage model.
BACKGROUND The purpose of this study was to compare standard gauze (SG) and advanced hemostatic dressings in use by military personnel in a no-hold model. METHODS A randomized, controlled trial was conducted using 36 swine. Animals underwent femoral arteriotomy, followed by 60 seconds of uncontrolled hemorrhage. After hemorrhage, packing with 1 of 3 dressings-SG, Combat Gauze (CG), or Celox R...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular surgery
دوره 50 3 شماره
صفحات -
تاریخ انتشار 2009