Topping-off technique prevents aggravation of degeneration of adjacent segment fusion revealed by retrospective and finite element biomechanical analysis

نویسندگان

  • Zhenqi Zhu
  • Chenjun Liu
  • Kaifeng Wang
  • Jian Zhou
  • Jiefu Wang
  • Yi Zhu
  • Haiying Liu
چکیده

AIM The aim of this study was to evaluate the effect of the Topping-off technique in preventing the aggravation of degeneration caused by adjacent segment fusion. METHODS Clinical parameters of patients who underwent L5-S1 posterior lumbar interbody fusion + interspinous process at L4-L5 (PLIF + ISP) with the Wallis system (Topping-off group) were compared retrospectively with those of patients who underwent solely PLIF. Pre- and post-operative x-ray measurements, visual analogue scale (VAS) scores, and Japanese Orthopaedic Association (JOA) scores were assessed in all subjects. Normal L1-S1 lumbosacral finite element models were established in accordance with the two types of surgery in our study, respectively. Virtual loading was added to assess the motility, disc pressure, and facet joint stress of L4-L5. RESULTS There were 22 and 23 valid cases included in the Topping-off and PLIF groups. No degeneration was observed in either group. Both VAS and JOA scores improved significantly post-operatively (P < 0.01). The intervertebral angle and lumbar lordosis of L4-L5 were both significantly increased (t = -2.89 and -2.68, P < 0.05 in the Topping-off group and t = -2.25 and -2.15, P < 0.05 in the PLIF group). In the Topping-off group, x-ray in dynamic position showed no significant difference in the angulation or distance of the anterior movement of the L4-L5 segment. The angle of hyper-extension and distance of the posterior movement of L4 were significantly decreased. In the PLIF group, both hyper-flexion and hyper-extension and posterior movement were increased significantly. In finite element analysis, displacement of the L4 vertebral body, pressure of the annulus fibrosus and nucleus pulposus, and stress of the bilateral facet joint were less in the Topping-off group under loads of anterior flexion and posterior extension. Facet joint stress on the left side of the L4-L5 segment was also less in the Topping-off group under left flexion loads. CONCLUSION Short-term efficacy and safety between Topping-off and PLIF were similar, whilst the Topping-off technique could restrict the hyper-extension movement of adjacent segments, prevent back and forth movement of proximal vertebrae, and decrease loads of intervertebral disc and facet joints.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cervical Disc Arthroplasty versus Disc Fusion: A Finite Element Study

INTRODUCTION: Disc degeneration is a natural process and is widely prevalent. The level of disc degeneration and the type of treatment varies from person to person. Fusion is a commonly chosen treatment option. However clinical and biomechanical studies have shown that spinal levels adjacent to a fusion experience increased motion and higher stress which may lead to adjacent-segment disease [1]...

متن کامل

Could the Topping-Off Technique Be the Preventive Strategy against Adjacent Segment Disease after Pedicle Screw-Based Fusion in Lumbar Degenerative Diseases? A Systematic Review

The "topping-off" technique is a new concept applying dynamic or less rigid fixation such as hybrid stabilization device (HSD) or interspinous process device (IPD) for the purpose of avoiding adjacent segment disease (ASD) proximal to the fusion construct. A systematic review of the literature was performed on the effect of topping-off techniques to prevent or decrease the occurrence of ASD aft...

متن کامل

Comparison of posterior versus transforaminal lumbar interbody fusion using finite element analysis

Objectives: To compare the influence of posterior lumbar interbody fusion (PLIF) and transforaminal lumbar interbody fusion (TLIF) on adjacent segment degeneration. Methods: The study was carried out in the Traumatology and Orthopedics Laboratory, Department of Traditional Chinese Medicine, Medical School, Jinan University, Guangzhou, China, between December 2013 and November 2014. A normal, he...

متن کامل

Analysis of the Biomechanical Characteristics of the Spinal Interspinous Implants

Spinal decompression surgery with spinal fusion is a widely used surgical procedure for the treatment of degenerative spine in the lumbar spine. However, it has been known that spinal decompression surgery causes the spinal instability. Some cadaveric and finite element (FE) studies have reported that adjacent segment degeneration may reduce adverse effects on the adjacent levels resulting from...

متن کامل

Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis

Interbody fusion with posterior instrumentation is a common method for treating lumbar degenerative disc diseases. However, the high rigidity of the fusion construct may produce abnormal stresses at the adjacent segment and lead to adjacent segment degeneration (ASD). As such, biodegradable implants are becoming more popular for use in orthopaedic surgery. These implants offer sufficient stabil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015