A software engine to justify the conclusions of an expert system for detecting renal obstruction on 99mTc-MAG3 scans.

نویسندگان

  • Ernest V Garcia
  • Andrew Taylor
  • Daya Manatunga
  • Russell Folks
چکیده

UNLABELLED The purposes of this study were to describe and evaluate a software engine to justify the conclusions reached by a renal expert system (RENEX) for assessing patients with suspected renal obstruction and to obtain from this evaluation new knowledge that can be incorporated into RENEX to attempt to improve diagnostic performance. METHODS RENEX consists of 60 heuristic rules extracted from the rules used by a domain expert to generate the knowledge base and a forward-chaining inference engine to determine obstruction. The justification engine keeps track of the sequence of the rules that are instantiated to reach a conclusion. The interpreter can then request justification by clicking on the specific conclusion. The justification process then reports the English translation of all concatenated rules instantiated to reach that conclusion. The justification engine was evaluated with a prospective group of 60 patients (117 kidneys). After reviewing the standard renal mercaptoacetyltriglycine (MAG3) scans obtained before and after the administration of furosemide, a masked expert determined whether each kidney was obstructed, whether the results were equivocal, or whether the kidney was not obstructed and identified and ranked the main variables associated with each interpretation. Two parameters were then tabulated: the frequency with which the main variables associated with obstruction by the expert were also justified by RENEX and the frequency with which the justification rules provided by RENEX were deemed to be correct by the expert. Only when RENEX and the domain expert agreed on the diagnosis (87 kidneys) were the results used to test the justification. RESULTS RENEX agreed with 91% (184/203) of the rules supplied by the expert for justifying the diagnosis. RENEX provided 103 additional rules justifying the diagnosis; the expert agreed that 102 (99%) were correct, although the rules were considered to be of secondary importance. CONCLUSION We have described and evaluated a software engine to justify the conclusions of RENEX for detecting renal obstruction with MAG3 renal scans obtained before and after the administration of furosemide. This tool is expected to increase physician confidence in the interpretations provided by RENEX and to assist physicians and trainees in gaining a higher level of expertise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RENEX: an expert system for the interpretation of 99mTc-MAG3 scans to detect renal obstruction.

UNLABELLED A renal expert system (RENEX) has been developed to assist physicians detect renal obstruction in patients undergoing pre- and postfurosemide 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) scans. RENEX uses quantitative parameters extracted from the dynamic renal scan data and heuristic rules in the form of a knowledge base (KB) obtained from expert interpreters to conclude whether a ki...

متن کامل

A SOFTWARE ENGINE TO JUSTIFY AN EXPERT SYSTEM’S CONCLUSIONS FOR DETECTING RENAL OBSTRUCTION FROM Tc-99m MAG3 SCANS

Objectives: We have previously developed a renal expert system (RENEX) as a decision support tool to assist in the interpretation of Tc-99m MAG3 scans to detect renal obstruction in patients referred for diuresis renography. A decision support system may give the right answer for the wrong reasons. This study is to describe and evaluate a software engine to justify the conclusions reached by RE...

متن کامل

Synthesis, formulation and quality control of 99mTc-MAG3, as a renal tubular 99mTc-radiopharmaceutical kit [Persian]

Radionuclidic techniques may provide assessment of glomerular filtration rate (GFR) effective renal plasma flow (ERPF) or individual renal function. Several agents were available for determination of these parameters such as ¹³¹I-OIH (O-iodohippurate) and different derivatives of DADS (Diamidodisulfur). OIH has the disadvantage of imparting a relatively high absorbed radiation dose to the...

متن کامل

Assessment of renal function in mice with unilateral ureteral obstruction using 99mTc-MAG3 dynamic scintigraphy

BACKGROUND Renal scintigraphy using 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) is widely used for the assessment of renal function in humans. However, the application of this method to animal models of renal disease is currently limited, especially in rodents. Here, we have applied 99mTc-MAG3 renal scintigraphy to a mouse model of unilateral ureteral obstruction (UUO) and evaluated its utility...

متن کامل

A camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]

Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 2007