Improving the transfer of near infrared prediction models by orthogonal methods

نویسندگان

  • B. Igne
  • Benoit Igne
  • Jean-Michel Roger
  • Sylvie Roussel
  • Véronique Bellon-Maurel
  • Charles R. Hurburgh
چکیده

Eight calibration transfer methods based on the removal of orthogonal signal were compared for the standardization of whole soybean protein and oil models. Dynamic orthogonal projection (DOP), transfer by orthogonal projection (TOP), error removal by orthogonal subtraction (EROS), orthogonal signal correction (OSC), and orthogonal projections to latent structures (O-PLS) as well as the modification and extension of some of these methods were compared in the transfer of models in intra and inter brand situations using two Foss Infratecs and two Bruins OmegAnalyzerGs. For each brand, a master was designated and its models transferred onto the second unit of its network and the two units of the second brand. Calibration models were transferable from brand to brand with similar or better __________________________ * Corresponding author. E-mail address: [email protected] 21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 precision than when each instrument was calibrated on its own calibration set (for Infratec 1229, the relative predictive determinant (RPD) increased in intra and inter-brand calibration transfer situations from 10.42 to 11.45 and 10.57, with DOP and EROS respectively) . Performance of each method was different across parameters, instruments, and validation sets. DOP modifications on the determination of the difference matrix showed promising results while TOP and EROS extensions to include variability specifically present in certain crop years did not bring any beneficial effects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Freshness Quality and Phosphate Residue of White Shrimp Products Using Near-Infrared Spectroscopy

 Background: The manufacturing of frozen shrimp is an important industry for the economy of Thailand. The objective of this study was to use Near-Infrared (NIR) spectroscopy to determine the freshness quality, including Total Volatile Basic Nitrogen (TVB-N) and Water Holding Capacity (WHC) of white shrimp (whole and chopped shrimp) and phosphate residues of shrimp. Methods: Sixty white shrimp ...

متن کامل

A Comparative Study Concerning Linear and Nonlinear Models to Determine Sugar Content in Sugar Beet by Near Infrared Spectroscopy (NIR)

This paper reports on the use of Artificial Neural Networks (ANN) and Partial Least Squareregression (PLS) combined with NIR spectroscopy (900-1700 nm) to design calibration models for thedetermination of sugar content in sugar beet. In this study a total of 80 samples were used as the calibration set,whereas 40 samples were used for prediction. Three pre-processing methods, including Multiplic...

متن کامل

Development of near infrared reflectance spectroscopy (NIRS) calibration model for estimation of oil content in a worldwide safflower germplasm collection

The development of NIRS calibration model as a rapid, precise, robust, and cost-effective method to estimate oil content in ground seeds of worldwide safflower germplasm collection grown under different agro-climatic conditions was the key objective of this research project. The oil content was measured by accelerated solvent extraction method in a total of 328 samples collected across 2004 (16...

متن کامل

Nondestructive Firmness Estimation of Tomato Fruit Using Near-Infrared Spectroscopy

Today, nondestructive methods are widely used to determine the quality of agricultural products. Meanwhile, visible and near-infrared (Vis/NIR) spectroscopy is regarded as one of the most widely used methods in the field of quality assessment of agricultural products. In this study, a system was developed to measure the Vis/NIR spectra of tomato fruit samples in the half-transmittance mode of m...

متن کامل

Change of Hemoglobin Concentration with nano particles can predict breast cancer using near infrared source?

Introduction: Early detection and treatment of breast cancer may be helping to save the lives of patients. Many new techniques have been urban to detect breast cancer. One of them is the use of nano-particles for accuracy and early diagnosis after photo transfer. In this study, rod gold nano particles was used according their ability to change light source transfer intensity. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010