Endothelial dysfunction assessment by flow-mediated dilation in a high-altitude population

نویسندگان

  • Walter S Calderón-Gerstein
  • Antonio López-Peña
  • Raúl Macha-Ramírez
  • Astrid Bruno-Huamán
  • Roxana Espejo-Ramos
  • Stephany Vílchez-Bravo
  • María Ramírez-Breña
  • Milagros Damián-Mucha
  • Adriana Matos-Mucha
چکیده

Introduction Endothelial function at high altitude has been measured only in populations that are genetically adapted to chronic hypoxia. The objective of this study was to evaluate endothelial dysfunction (ED) in a nongenetically adapted high-altitude population of the Andes mountains, in Huancayo, Peru (3,250 meters above sea level). Methods Participants included 61 patients: 28 cases and 33 controls. The cases were subjects with hypertension, diabetes mellitus, obesity, or a history of stroke or coronary artery disease. Flow-mediated vasodilation (FMD) of the brachial artery was measured in the supine position, at noon, after 5 minutes of resting. The brachial artery was identified above the elbow. Its basal diameter was measured during diastole, and FMD was tested after 5 minutes of forearm ischemia. Intima-media complex in the right carotid artery was also determined. An increase in the artery's baseline diameter <10% indicated a positive test. Endothelium-independent vasodilation was evaluated with sublingual nitrate administration. The intima-media complex in the right carotid artery was also measured. Results 100% of diabetics had ED; ED was also found in 68.8% of obese individuals, 55% of hypertensive patients, and 46.5% of controls. Age, height, body mass index, and waist diameter were higher in the cases as compared with the controls. A total of 57.9% (n=11) of the cases and 45.2% (n=19) of the controls presented ED. Patients without ED had a mean increase in brachial artery diameter of 23.16%, while in those with ED it was only 3.84%. Individuals with diabetes or hypertension had a greater thickness of the carotid artery intima media layer (1.092 versus 0.664 cm) (p=0.037). A positive test for ED was associated with a greater basal diameter of the brachial artery (4.66±0.62 versus 4.23±0.59 cm) (p=0.02). A total of 7 patients presented paradoxical response, developing posthyperemia vasoconstriction. Discussion The proportion of ED was high among controls and among patients with risk factors. Controls showed better FMD profiles than subjects studied in Tibet and the Himalayas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impaired systemic endothelial function in patients with pseudoexfoliation syndrome.

Pseudoexfoliation syndrome (PEX) is the most common clinical precursor of open-angle glaucoma. Recent studies have shown that pseudoexfoliative material is widely distributed throughout the body, including blood vessels. The aim of our study was to evaluate endothelial function in the brachial artery of patients with pseudoexfoliation syndrome. We prospectively examined 23 patients with PEX (me...

متن کامل

Endothelial Function in Systemic Lupus Erythematosus: Relationship to Disease Activity, Cardiovascular Risk Factors, Corticosteroid Therapy, and Coronary Calcification

OBJECTIVES Endothelial dysfunction is frequently present in patients with systemic lupus erythematosus and may increase their risk of premature coronary artery disease. In this pilot study we have characterized the relationship between endothelial function, measures of disease activity, and cardiovascular risk factors in patients with lupus. METHODS Clinical characteristics and cardiovascular...

متن کامل

Use of ultrasound for non-invasive assessment of flow-mediated dilation.

The pathological complications of atherosclerosis, namely heart attacks and strokes, remain the leading cause of mortality in the Western world. Preceding atherosclerosis is endothelial dysfunction. There is therefore interest in the application of non-invasive clinical tools to assess endothelial function. The flow-mediated dilation (FMD) test is the standard tool used to assess endothelial fu...

متن کامل

Serum myeloperoxidase levels independently predict endothelial dysfunction in humans.

BACKGROUND In vitro and animal studies demonstrate that myeloperoxidase catalytically consumes nitric oxide as a substrate, limiting its bioavailability and function. We therefore hypothesized that circulating levels of myeloperoxidase would predict risk of endothelial dysfunction in human subjects. METHODS AND RESULTS Serum myeloperoxidase was measured by enzyme-linked immunoassay, and brach...

متن کامل

Impairment of endothelial function--a possible mechanism for atherosclerosis of a high-fat meal intake.

INTRODUCTION Endothelial dysfunction is known to occur in patients with coronary artery disease. Flow-mediated dilation of the brachial artery using Doppler ultrasound is a non-invasive technique for the assessment of endothelial function. The objective of the study was to use the above method to evaluate the pathophysiology of high-fat (HF) intake on endothelial function in a local population....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2017