Performance criteria for reference measurement procedures and reference materials.
نویسندگان
چکیده
The concept of metrological traceability of measurement results to property values assigned to measurement standards of higher metrological order or to the International System of Units (SI) through sequential calibrations, using reference materials and reference measurement procedures, plays a key role in ensuring that end user measurement procedures perform at an acceptable level in the clinical context. The aim is that measurement results produced over time or by different end users or with different end user measurement procedures for the same measurand will be equivalent within their corresponding uncertainties. These goals can only be reached under certain conditions and if requirements laid down in international standards on calibration concepts, reference measurement procedures and reference materials are fulfilled. Calibration hierarchies have to be implemented correctly and parameters contributing to measurement uncertainty and systematic bias need to be controlled and eliminated, respectively, by technically improving methods and reference materials and intermediate calibrators used for effectively achieving equivalence of measurement results and for meeting analytical performance requirements for in vitro diagnostic devices.
منابع مشابه
The need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography
Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low ...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملDetermining the Reference Value in Forest Policy of Kalgachi Local System, Zagros Forest, Chaharmahal and Bakhtiari Province
Sustainable forest management standards and measurement instruments subject and use them as the main tool is very important for monitoring and control in forest management. Sustainable progress monitoring and measuring possible by tools and standards. Tools and standards to help sustainable forest management can be more accurate and better information provided to forest managers and decision-ma...
متن کاملEstablishing Reference Systems in Laboratory Medicine on the Basis of ISO/CEN Standards
ISO/IEC has issued several International Standards concerning the concept of traceability in laboratory medicine. prEN ISO 17511 Metrological traceability of values assigned to calibrators and control materials, prEN ISO 18153 Metrological traceability of values for catalytic concentrations of enzymes assigned to calibrators and control materials, prEN ISO 15193 Presentation of reference measur...
متن کاملCommutability still matters.
Commutability is a property of a reference material such that values measured for that reference material and for representative clinical samples have the same relationship between 2, or more, measurement procedures for the same measurand (1, 2 ). Commutability is required when a reference material will be used as a common calibrator for clinical laboratory measurement procedures or will be use...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 53 6 شماره
صفحات -
تاریخ انتشار 2015