The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability

نویسندگان

  • Gabriel Loor
  • Andres Schuster
  • Vincent Cruz
  • Aldo Rafael
  • William J. Stewart
  • James Diaz
  • Kenneth McCurry
چکیده

BACKGROUND The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis (Edwards Lifesciences, Irvine, CA) is a low-profile version of the earlier Perimount valve that uses the ThermaFix process for enhanced calcium removal. The Magna valve has been in use since 2008, yet no publication, until now, has verified its intermediate-term safety and efficacy. METHODS From 2008 through 2011 (our 4-year study period), 70 Magna valves were implanted in the mitral position at a single institution (the Cleveland Clinic). Echocardiograms were prospectively interpreted. For this study, we reviewed patients' charts; endpoints included hemodynamic measurements, in-hospital morbidity and mortality, valve-related events, resource utilization, and 5-year survival rates. RESULTS The mean patient age was 68 years; 43 % of the patients had New York Heart Association (NYHA) class III or IV disease, and 51.4 % had moderately severe, or worse, mitral regurgitation (MR). For 43 % of the patients, the Magna valve implantation was a reoperation. For 83 %, the Magna valve implantation also included a concomitant cardiac procedure. The median survival rate was 4.7 years and 90 % of patients were free from significant structural valve degeneration at 5 years. Preoperative atrial fibrillation, ischemic MR, intraaortic balloon pump placement, cardiogenic shock, cardiac arrest, and renal failure were associated with increased mortality. Right ventricular systolic pressure decreased from 50 mmHg preoperatively to 40 mmHg postoperatively, according to our matched-pair analysis (P = 0.003). Per their final echocardiogram during our study period, 98 % of surviving patients had trivial or no MR, one patient had mild MR, and one patient had severe MR. CONCLUSIONS Our 5-year experience indicates that the Magna valve offers excellent intermediate-term durability and substantial echocardiographic improvement; its low-profile design make it ideal for reoperations and for concomitant cardiac procedures, including valve replacement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Structural valve deterioration of a mitral Carpentier-Edwards pericardial bioprosthesis in an 87-year-old woman 16 years after its implantation

The second-generation pericardial valve, the Carpentier-Edwards perimount bioprosthetic (CEP) valve, shows dramatically improved durability as compared to the first-generation pericardial valve, and excellent performance has been obtained, in both the aortic and mitral positions. Especially in elderly patients with an implanted CEP valve, reoperation due to structural valve deterioration (SVD) ...

متن کامل

Very long-term outcomes of the Carpentier-Edwards Perimount valve in aortic position.

BACKGROUND The Carpentier-Edwards Perimount pericardial bioprosthesis (Edwards Lifesciences, Irvine, CA) has demonstrated good long-term outcomes, but its durability remains unclear depending on age at implantation. We report our 20-year experience with the Perimount valve implanted in the aortic position, with particular attention to the probability and time to reoperation required due to biop...

متن کامل

Cuff leakage, not paravalvular leakage, in the Carpentier Edwards PERIMOUNT Magna Ease aortic bioprosthesis.

Though the Carpentier Edwards PERIMOUNT Magna Ease valve is a bioprosthesis with documented excellent haemodynamics and easy implantability, this valve has a gap between the cobalt-chromium-nickel alloy stent and silicone sewing ring. This gap, which is widest just below each of the three commissural struts, lacks silicone and leaves the two-layer polytetrafluoroethylene fabric unsupported and ...

متن کامل

Long-term results of aortic valve replacement with mechanical prosthesis or carpentier-edwards perimount bioprosthesis in Japanese patients according to age.

BACKGROUND The long-term results of aortic valve replacement (AVR; n=737) with bileaflet mechanical prosthesis (MP) or Carpentier-Edwards Perimount bioprostheses (BP) were evaluated in different age groups. METHODS AND RESULTS: Since 1981, a total of 737 prostheses (424 bileaflet MP vs. 313 BP) were implanted for AVR in 278 patients aged ≥70 years (79 MP vs. 199 BP), in 191 patients aged 60-69 ...

متن کامل

Acute thrombosis of bioprosthetic mitral valve

We report a case of acute thrombosis of bioprosthetic mitral valve in a 59 year-old Korean female, who underwent a mitral valve replacement with a 25 mm Carpentier - Edwards PERIMOUNT Plus bioprosthesis (Edwards Lifesciences, Inc.; Irvine, CA, USA) and a mini-Maze procedure for correction of mitral stenosis (MS) and atrial fibrillation (AF). On the 10th postoperative day, the patient began to c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016