Standardisation of cardiac troponin I measurement: past and present.

نویسندگان

  • Jillian R Tate
  • David M Bunk
  • Robert H Christenson
  • Alexei Katrukha
  • James E Noble
  • Robert A Porter
  • Heinz Schimmel
  • Lili Wang
  • Mauro Panteghini
چکیده

The laboratory measurement of cardiac troponin (cTn) concentration is a critical tool in the diagnosis of acute myocardial infarction (MI). Current cTnI assays produce different absolute troponin numbers and use different clinical cut-off values; hence cTnI values cannot be interchanged, with consequent confusion for clinicians. A recent Australian study compared patient results for seven cTnI assays and showed that between-method variation was approximately 2- to 5-fold. A major reason for poor method agreement is the lack of a suitable common reference material for the calibration of cTnI assays by manufacturers. Purified complexed troponin material lacks adequate commutability for all assays; hence a serum-based secondary reference material is required for cTnI with value assignment by a higher order reference measurement procedure. There is considerable debate about how best to achieve comparability of results for heterogeneous analytes such as cTnI, whether it should be via the harmonisation or the standardisation process. Whereas harmonisation depends upon consensus value assignment and uses those commercial methods which give the closest agreement at the time, standardisation comes closer to the true value through a reference measurement system that is based upon long-term calibration traceability. The current paper describes standardisation efforts by the International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Standardization of cTnI (IFCC WG-TNI) to establish a reference immunoassay measurement procedure for cTnI of a higher order than current commercial immunoassay methods and a commutable secondary reference material for cTnI to which companies can reference their calibration materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی غلظت سرمی تروپونین I در بیماران مبتلا به تشنج غیرعارضه‌دار صرعی سالم از نظر قلبی

   Background & Aim : Sudden Unexpected Death after Epilepsy (SUDEP) is one of potentially lethal side effects of the seizures. Cardiac arrhythmia and myocardial damage have been postulated as underlying causes. On the other hand, serum cardiac troponin I (cTnI) level is one of the most specific cardiac markers for myocardial damage. Therefore, the aim of the present study was to evaluate the l...

متن کامل

سنجش مقادیر تروپونین ? قلبی در بیماران مبتلا به آمبولی حاد ریه و ارتباط آن با اختلال عملکرد بطن راست

Background and purpose: Right ventricular dysfunction is common in major pulmonary embolisms. The purpose of this study was to evaluate the prevalence and diagnostic utility of cardiac troponin I and also to identify patients with RV dysfunction in pulmonary embolism. Materials and methods: This study was conducted on 42 patients with pulmonary embolism in Ekbatan Hospital, in Hamedan city. ...

متن کامل

Analysis of the relation between coping ways with stress and Cardiac Biomarker Troponin I in coronary heart disease patients

Introduction: Coping ways with stress in coronary heart disease patients can lead to significant changes in levels of Cardiac Biomarker Troponin I, but researchers had not explored it empirically. So, the main objective of this study was to identify the relationship between coping ways with stress and Cardiac Biomarker Troponin I and also, finding coping ways that predict changes in the concent...

متن کامل

Evaluation of cardiac troponin I (cTnI), electrocardiography, creatine kinase (CK) and aspartate aminotransferase (AST) in diagnosis of selenium deficiency in Markhoz goat kids breed

BACKGROUND: Cardiac Troponin I (cTnI) is known as a cardiac biomarker in determining the myocardial damage of diseases which affect the heart muscle. OBJECTIVES: This study aims to evaluate the serum cTnI concentration in Markhoz Breed goats suffering selenium (Se) deficiency and its correlation with electrocardiographic parameters, and activity of creatine kinase (CK) and aspartate aminotransf...

متن کامل

Evaluation of cardiac troponin I, atrial natriuretic peptide and some oxidative/antioxidative biomarkers in the serum and hemolysate of trained Arabian horses after exercise

Background: Limited information existed on performance tests in Iranian Arab horses. Aims: The objective of this study is to investigate time related changes of cardiac troponin I (cTnI), atrial natriuretic peptide (ANP) and oxidative/antioxidant biomarkers in the serum of Arabian horses before and after regular training. Methods: Blood samples were collected from jugular vein of 25 Arabian hor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pathology

دوره 42 5  شماره 

صفحات  -

تاریخ انتشار 2010