Effect of ACL Reconstruction and Tibial Rotation on Anterior Knee Laxity.

نویسندگان

  • K M Guskiewicz
  • D H Perrin
  • D E Martin
  • D M Kahler
  • B M Gansneder
  • F C McCue
چکیده

The anterior cruciate ligament (ACL) is the primary restraint to anterior translation of the tibia on the femur. Research suggests that resistance to anterior translation changes as the tibia is rotated internally and externally. This study assessed the degree to which ACL reconstruction and tibial rotation affects anterior knee laxity. Nine subjects with ACL lesions and functional instabilities participated in the study. Subjects were measured 1 to 10 days before surgery and 6 to 8 months after ACL reconstruction using the KT-1000 knee arthrometer. A mechanical leg stabilizer was used to assess anterior translation at 20 degrees of knee flexion in three positions: internal rotation of 15 degrees , neutral, and external rotation of 15 degrees . Subjects were measured at 89 and 67 N of anterior force. Data were analyzed with a three-factor (test x position x force) repeated measures ANOVA. Following surgery, reduction in laxity (mm) for the three positions (internal rotation, neutral, and external rotation) was 1.9, 2.8, and 3.4, respectively, at 89 N and 1.5, 2.0, and 2.6, respectively, at 67 N. The degree of reduction in laxity (presurgery to postsurgery) was dependent upon rotation and force, and was greatest in external rotation and least in internal rotation pre- to postsurgery. We concluded that ACL reconstruction using a patellar tendon graft significantly decreased anterior tibial translation at all three positions, but a greater amount of reduction was observed postsurgically at the externally rotated position. This supports the theory that mechanical blocks and secondary restraints such as a taut mid-third of the iliotibial tract may interfere with clinical laxity tests in some positions of tibial rotation. Fixing the tibia in an externally rotated position may decrease the effect of secondary restraints and improve sensitivity in testing for ACL laxity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical evaluation of knee joint laxities and graft forces after anterior cruciate ligament reconstruction by anteromedial portal, outside-in, and transtibial techniques.

BACKGROUND Recently, anatomic anterior cruciate ligament (ACL) reconstruction is emphasized to improve joint laxity and to potentially avert initiation of cartilage degeneration. There is a paucity of information on the efficacy of ACL reconstructions by currently practiced tunnel creation techniques in restoring normal joint laxity. STUDY DESIGN Controlled laboratory study. HYPOTHESIS Ante...

متن کامل

Biomechanical comparison of anatomic single- and double-bundle anterior cruciate ligament reconstructions: an in vitro study.

BACKGROUND Arthroscopic identification of the anteromedial (AM) and posterolateral (PL) bundle locations of the anterior cruciate ligament (ACL) has facilitated an improved quantitative description of ACL anatomy. Few studies have directly compared the biomechanical laxity of anatomic single-bundle (SB) versus anatomic double-bundle (DB) ACL reconstruction techniques based on precise anatomic d...

متن کامل

A new tibial coordinate system improves the precision of anterior-posterior knee laxity measurements: A cadaveric study using Roentgen stereophotogrammetric analysis

Roentgen stereophotogrammetric analysis (RSA) can be used to measure changes in anterior-posterior (A-P) knee laxity after anterior cruciate ligament (ACL) reconstruction. Previous measurements of A-P knee laxity using RSA have employed a tibial coordinate system with the origin placed midway between the tips of the tibial-eminences. However, the precision in measuring A-P knee laxity might be ...

متن کامل

Effect of Tibial Rotation at Time of Graft Fixation in Single and Double Bundle ACL reconstructed Knees

Introduction: Even though, the interest of scientific research is focussed on the effect and results of DB reconstruction, several aspects of how to improve the rotational stability of the human knee after single bundle reconstruction remain unsolved. The effect of tibial rotation at the time of graft fixation in ACL reconstruction remains unknown. Theoretically, different tibial rotation when ...

متن کامل

Using navigation to measure rotation kinematics during ACL reconstruction.

Rotational kinematics of the knee is not fully restored after single-bundle anterior cruciate ligament (ACL) reconstruction. Cadaveric experiments using knee testing machines have suggested anatomical reconstruction replacing the anteromedial and posterolateral bundles could restore knee kinematics more effectively than single-bundle reconstruction. However, practical tools to objectively asses...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of athletic training

دوره 30 3  شماره 

صفحات  -

تاریخ انتشار 1995