Correlation between central corneal thickness and intraocular pressure peak and fluctuation during the water drinking test in glaucoma patients

نویسندگان

  • Rafael Lacerda Furlanetto
  • Antonio Carlos Facio
  • Marcelo Hatanaka
  • Remo Susanna Junior
چکیده

OBJECTIVE To investigate the correlation between central corneal thickness and outflow facility assessed by intraocular pressure peak and fluctuation during the water drinking test. METHODS Fifty-five newly diagnosed primary open-angle glaucoma patients submitted to central corneal thickness measurements and water drinking test were enrolled in this retrospective study.;. Patients were divided into three groups according to their central corneal thickness. Pearson's Correlation test was performed in the groups with lower and higher pachymetric values. RESULTS The mean age was 65,65 ± 28,28 years; 63,63% were female and 52,72% were caucasian. The mean central corneal thickness was 544,32 ± 36,86 µm, and the mean baseline intraocular pressure was 23,36 ± 6,26 mmHg. During the water drinking test, the mean intraocular pressure peak and mean intraocular pressure fluctuation were 30,43 ± 8,13 mmHg and 31,46 ± 18,46%, respectively. No relevant correlation was detected between the central corneal thickness and the intraocular pressure peak (r² = 0,021) or between the central corneal thickness and the intraocular pressure fluctuation (r² = 0,011). Group 1 presented a mean central corneal thickness of 505,81 ± 13,86 µm, and Group 3 was 583,55 ± 27,87 µm (p = 0,001). The mean intraocular pressure peak was 31,05 ± 9,05 mmHg and 27,83 ± 4,92 mmHg in Group 1 and in Group 3, respectively (p = 0,193). The difference of intraocular pressure fluctuation was not statistically significant between Group 1 (mean 28,47 ± 16,25%) and Group 3 (mean 33,27 ± 21,27%) (p = 0,43). CONCLUSION In our case series, no correlation was found between central corneal thickness and water drinking test results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

[Comparative study between diurnal intraocular pressure curve and the association of ambulatory intraocular pressure curve with the water-drinking test in open angle glaucoma, normal tension glaucoma and normal eyes].

PURPOSE To evaluate and correlate the peaks and the fluctuation of intraocular pressure seen in the association of the ambulatory intraocular pressure curve with the water-drinking test versus the peaks and the fluctuation seen in the daily intraocular pressure curve. METHODS The sample was as follows: 77 eyes belonging to 77 patients who were divided into three groups composed of 31 eyes bel...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Intraocular pressure dynamics with prostaglandin analogs: a clinical application of the water-drinking test

AIM To evaluate the clinical applicability of the water-drinking test in treatment-naive primary open-angle glaucoma patients. METHODS Twenty newly diagnosed primary open-angle glaucoma patients and 20 healthy controls were enrolled in this prospective study. The water-drinking test was performed at baseline and 6 weeks and 3 months after prostaglandin analog treatment. Peak and fluctuation o...

متن کامل

Correlation Between the Water Drinking Test and Modified Diurnal Tension Curve in Untreated Glaucomatous Eyes

OBJECTIVES To investigate the correlation and agreement between the intraocular pressure peaks detected during the water drinking test and the modified diurnal tension curve in untreated glaucomatous eyes. INTRODUCTION It has been suggested that the intraocular pressure peaks detected during the water drinking test predict the peaks observed during a 24-hour diurnal tension curve. A more feas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 65  شماره 

صفحات  -

تاریخ انتشار 2010