New fontanometer for continuous estimation of intracranial pressure in the newborn.
نویسندگان
چکیده
Intracranial pressure was estimated by a new pneumatic applanation fontanometer in babies in intensive care. A close correlation with cerebrospinal fluid pressure was found on 35 separate occasions. In 12 control babies the mean (SD) fontanelle pressure was 5.2 (2.2) cm H2O, in eight with a hypoxic-ischaemic encephalopathy it was 12.6 (4.3) cm H2O, and in nine with post-haemorrhagic hydrocephalus it was 10.8 (4.3) cm H2O. In four babies monitored continuously over seven days the correlation remained good. The fontanometer enables pressure to be monitored accurately, continuously, and non-invasively in neonates at risk of raised intracranial pressure.
منابع مشابه
Non-invasive measurement of intracranial pressure in the newborn and the infant: the Rotterdam teletransducer.
Knowledge of intracranial pressure may be important in many clinical situations in neonates and young infants. The best way to obtain this information would be a non-traumatic procedure. In order to test the reliability of a new fontanometer, the Rotterdam teletransducer, 25 simultaneous measurements of cerebrospinal fluid (CSF) pressure and anterior fontanelle pressure (AFP) were performed. Me...
متن کاملIntracranial pressure in a case of isolated fourth ventricle.
Since the report by Lundberg (1960), the importance of analysis of pressure waves has been recognized with respect to the intracranial pressure, apart from the level of pressure. More recently, various instruments for measuring the intracranial pressure have been developed and measurements of the extradural and intraventricular pressure have become relatively easy. At the same time, efforts to ...
متن کاملMeasurement of fontanelle pressure (Part I). A new instrument for non-invasive measurement of intracranial pressure via the anterior fontanelle.
Intracranial pressure (ICP) is one of the most important parameters for evaluating intracranial conditons. The skulls of newborns and infants, unlike the tightly sutured skull of adults, provide non-invasive access for measurement of ICPs via the anterior fontanelle. A new transducer has been developed which is convenient for non-invasive, continuous measurement of intracranial pressure through...
متن کاملPerformance of Biological hydrogen Production Process from Synthesis Gas, Mass Transfer in Batch and Continuous Bioreactors
Biological hydrogen production by anaerobic bacterium, Rhodospirillum rubrum was studied in batch and continuous bioreactors using synthesis gas (CO) as substrate. The systems were operated at ambient temperature and pressure. Correlations available in the literature were used to estimate the gas-liquid mass transfer coefficients (KLa) in batch reactor. Based on experimental results for the con...
متن کاملMethods of measuring intracranial pressure via the fontanelle without puncture.
It is suggested that non-invasive techniques for measuring intracranial pressure should be suitable for use in the unsedated infant and should be capable of measuring pressure continuously. Methods described by other authors are reviewed. After investigation of 18 patients the technique relying upon the pulsation of the fontanelle described by Purin was rejected as being difficult to perform an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood
دوره 62 2 شماره
صفحات -
تاریخ انتشار 1987