Functional Outcome, Revision Rates and Mortality after Primary Total Hip Replacement – A National Comparison of Nine Prosthesis Brands in England

نویسندگان

  • Mark Pennington
  • Richard Grieve
  • Nick Black
  • Jan H. van der Meulen
چکیده

BACKGROUND The number of prosthesis brands used for hip replacement has increased rapidly, but there is little evidence on their effectiveness. We compared patient-reported outcomes, revision rates, and mortality for the three most frequently used brands within each prosthesis type: cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed), and hybrid (Exeter V40 Trilogy, Exeter V40 Trilogy, and CPT Trilogy). METHODS AND FINDINGS We used three national databases of patients who had hip replacements between 2008 and 2011 in the English NHS to compare functional outcome (Oxford Hip Score (OHS) ranging from 0 (worst) to 48 (best)) in 43,524 patients at six months. We analysed revisions and mortality in 187,201 patients. We used multiple regression to adjust for pre-operative differences. Prosthesis type had an impact on post-operative OHS and revision rates (both p<0.001). Patients with hybrid prostheses had the best functional outcome (mean OHS 39.4, 95%CI 39.1 to 39.7) and those with cemented prostheses the worst (37.7, 37.3 to 38.1). Patients with cemented prostheses had the lowest reported 5-year revision rates (1.3%, 1.2% to 1.4%) and those with cementless prostheses the highest (2.2%, 2.1% to 2.4%). Differences in mortality according to prosthesis type were small and not significant (p = 0.06). Functional outcome varied according to brand among cemented (p = 0.05, with Exeter V40 Duration having the best) and cementless prostheses (p = 0.01, with Corail Pinnacle having the best). Revision rates varied according to brand among hybrids (p = 0.05, with Exeter V40 Trident having the lowest). CONCLUSIONS Functional outcomes were better with cementless cups and revision rates were lower with cemented stems, which underlies the good overall performance of hybrids. The hybrid Exeter V40 Trident seemed to produce the best overall results. This brand should be considered as a benchmark in randomised trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Setting benchmark revision rates for total hip replacement: analysis of registry evidence.

OBJECTIVE To compare 10 year revision rates for frequently used types of primary total hip replacement to inform setting of a new benchmark rate in England and Wales that will be of international relevance. DESIGN Retrospective cohort study. SETTING National Joint Registry. PARTICIPANTS 239 000 patient records. MAIN OUTCOME MEASURES Revision rates for five frequently used types of total...

متن کامل

Revision Rates after Primary Hip and Knee Replacement in England between 2003 and 2006

BACKGROUND Hip and knee replacement are some of the most frequently performed surgical procedures in the world. Resurfacing of the hip and unicondylar knee replacement are increasingly being used. There is relatively little evidence on their performance. To study performance of joint replacement in England, we investigated revision rates in the first 3 y after hip or knee replacement according ...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013