Comparison between Thermal Desorption Tubes and Stainless Steel Canisters Used for Measuring Volatile Organic Compounds in Petrochemical Factories.

نویسندگان

  • Cheng-Ping Chang
  • Tser-Cheng Lin
  • Yu-Wen Lin
  • Yi-Chun Hua
  • Wei-Ming Chu
  • Tzu-Yu Lin
  • Yi-Wen Lin
  • Jyun-De Wu
چکیده

OBJECTIVE The purpose of this study was to compare thermal desorption tubes and stainless steel canisters for measuring volatile organic compounds (VOCs) emitted from petrochemical factories. METHODS Twelve petrochemical factories in the Mailiao Industrial Complex were recruited for conducting the measurements of VOCs. Thermal desorption tubes and 6-l specially prepared stainless steel canisters were used to simultaneously perform active sampling of environmental air samples. The sampling time of the environmental air samples was set up on 6 h close to a full work shift of the workers. A total of 94 pairwise air samples were collected by using the thermal adsorption tubes and stainless steel canisters in these 12 factories in the petrochemical industrial complex. To maximize the number of comparative data points, all the measurements from all the factories in different sampling times were lumped together to perform a linear regression analysis for each selected VOC. Pearson product-moment correlation coefficient was used to examine the correlation between the pairwise measurements of these two sampling methods. A paired t-test was also performed to examine whether the difference in the concentrations of each selected VOC measured by the two methods was statistically significant. RESULTS The correlation coefficients of seven compounds, including acetone, n-hexane, benzene, toluene, 1,2-dichloroethane, 1,3-butadiene, and styrene were >0.80 indicating the two sampling methods for these VOCs' measurements had high consistency. The paired t-tests for the measurements of n-hexane, benzene, m/p-xylene, o-xylene, 1,2-dichloroethane, and 1,3-butadiene showed statistically significant difference (P-value < 0.05). This indicated that the two sampling methods had various degrees of systematic errors. Looking at the results of six chemicals and these systematic errors probably resulted from the differences of the detection limits in the two sampling methods for these VOCs. CONCLUSIONS The comparison between the concentrations of each of the 10 selected VOCs measured by the two sampling methods indicted that the thermal desorption tubes provided high accuracy and precision measurements for acetone, benzene, and 1,3-butadiene. The accuracy and precision of using the thermal desorption tubes for measuring the VOCs can be improved due to new developments in sorbent materials, multi-sorbent designs, and thermal desorption instrumentation. More applications of thermal desorption tubes for measuring occupational and environmental hazardous agents can be anticipated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of qualitative and quantitative of volatile organic compounds of ambient air in the Mahshahr Petrochemical Complex in 2009.

BACKGROUND Volatile organic compounds (VOCs) are human-made chemicals widely spread in the environment and produced by petrochemical industries and petroleum refineries. The aim of this research was to evaluate the distribution of VOCs in the ambient air of Mahshahr Petrochemical Complex, Iran. METHODS This study was a cross-sectional research performed in 2009. We used the method numbered 15...

متن کامل

Development of second-generation sample enrichment probe for improved sorptive analysis of volatile organic compounds.

The sample enrichment probe (SEP) has recently been introduced as a user-friendly and cost-effective method for the sorptive extraction of volatile organic analytes from gaseous and aqueous samples for GC and GC-MS analyses. In a further development of the SEP technique, thinner polydimethylsiloxane (PDMS) tubing on polyimide-coated fused silica, instead of stainless steel rods or stalks, were ...

متن کامل

Measurement & Monitoring: 18th Quarterly Literature Update

24-Hour Diffusive Sampling of 1,3-Butadiene in Air onto Carbopack X Solid Adsorbent Followed by Thermal Desorption/GC/MS Analysis: Feasibility Study McClenny, W.A., D.A. Whitaker, K.D. Oliver, H.H. Jacumin Jr., and E.H. Daughtrey Jr. Symposium on Air Quality Measurement Methods and Technology, Research Triangle Park, NC, April 20-22, 2004 [EPA 600-04-062; NTIS PB2004-106812] Diffusive sampling ...

متن کامل

Description of the analysis of a wide range of volatile organic compounds in whole air samples collected during PEM-tropics A and B.

A large number of hydrocarbons, halocarbons, and organic nitrates were quantified in whole air samples acquired for the NASA-sponsored GTE missions PEM-Tropics A and B. The samples were collected in electro-polished stainless steel canisters from two aircraft while flying over the Pacific Basin. Two nominally identical multicolumn multidetector gas chromatographic analytical systems were employ...

متن کامل

Field sampling method for quantifying odorants in humid environments.

Most air quality studies in agricultural environments use thermal desorption analysis for quantifying semivolatile organic compounds (SVOCs) associated with odor. The objective of this study was to develop a robust sampling technique for measuring SVOCs in humid environments. Test atmospheres were generated at ambient temperatures (23 +/- 1.5 degrees C) and 25, 50, and 80% relative humidity (RH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 60 3  شماره 

صفحات  -

تاریخ انتشار 2016