Prevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves.

نویسندگان

  • D Georgiadis
  • D G Grosset
  • A Kelman
  • A Faichney
  • K R Lees
چکیده

BACKGROUND AND PURPOSE Transcranial Doppler detection of microemboli is widely described, but there is no clear evidence of the clinical significance or nature of the embolic material in vivo. Thromboembolism is a major cause of morbidity in patients with prosthetic cardiac valves. We undertook this study to evaluate the prevalence and the acoustic characteristics of microembolic signals in three groups of patients with different prosthetic valves. METHODS One hundred seventy-nine patients with prosthetic cardiac valves (85 Björk-Shiley, 56 Medtronic-Hall, and 38 Carpentier-Edwards) and 25 normal subjects were examined using transcranial Doppler. Monitoring time was 30 minutes over the right middle cerebral artery. RESULTS The prevalence and numbers of embolic signals were significantly higher in patients with Björk-Shiley compared with those with Medtronic-Hall and Carpentier-Edwards valves (89% versus 50% and 53%, respectively; P < .001, chi 2; 156 [112, 204] versus 2 [1, 4] and 2 [1, 4] signals/h, respectively; median [95% nonparametric confidence interval], both P < .001, multiple comparisons, Bonferroni correction). The signal intensity was significantly higher in patients with Björk-Shiley and Medtronic-Hall valves than patients with Carpentier-Edwards valves (2435 [2345, 2527] and 2120 [1745, 2483] versus 225 [184, 287] power units, median [95% confidence interval], both P < .001). No correlation was found between embolic signal numbers and clinical parameters including history of neurological deficit, cardiac rhythm, duration of artificial valve, previous cardiac operations, or intensity of anticoagulation. Embolic signals were not detected in any of the control subjects. CONCLUSIONS Our data showed that the prevalence, quantity, and acoustic characteristics of Doppler embolic signals differ in patients having three different types of prosthetic heart valves. However, no correlation with clinical parameters was identified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence of transcranial Doppler-detected cerebral microemboli in patients referred for echocardiography.

BACKGROUND AND PURPOSE Transcranial Doppler can detect cerebral microemboli. These emboli may be a risk factor for embolic stroke. We studied the prevalence of microemboli in patients referred for echocardiography. METHODS Forty-two patients were evaluated. Patients were studied with continuous monitoring over one middle cerebral artery for 30 minutes, and the number of microemboli was record...

متن کامل

Pregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves

There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...

متن کامل

Occurrence and clinical impact of microembolic signals during or after cardiosurgical procedures.

BACKGROUND AND PURPOSE Microembolic signals (MESs) are detectable within the transcranial Doppler frequency spectrum downstream from vascular atherothrombotic or cardiothrombotic lesions. A frequent occurrence of MESs has also been shown during bypass surgery or after mechanical valve implantation. We sought to compile the knowledge on MES prevalence, the clinical impact of these cardiogenic ME...

متن کامل

Microemboli Monitoring in Ischemic Stroke

The detection is made possible because of the acoustic impedance between microemboli and blood, which increases the ultrasound intensity. Microemboli are transient (<100ms), high intensity (> 3dB) and unidirectional signal which are accompanied by a characteristic click or chirp sound (Ringelstein, Droste et al. 1998). The origin of microemboli are usually from an atheromatous plaque in the car...

متن کامل

مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی

In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 1994