Assessment of Vibrations from a Seismic Test Facility

نویسندگان

  • Yong Keat LEE
  • Neil MACKENZIE
چکیده

The recent earthquakes in Christchurch led to the redevelopment of the University of Canterbury’s Seismic Equipment Laboratory (SEL). The SEL facility will involve the testing of building structures subject to simulated static and dynamic displacements from earthquakes, with a reaction wall and floor used to exert loads by way of hydraulic actuators on test specimens, and shaker tables used to test built forms separately or in combination. These tests can generate significant ground vibration, which has the potential to affect the use of nearby buildings housing sensitive equipment. This paper will outline measurements and analysis carried out to predict the likely vibration levels at the footings and within adjoining buildings. It also outlines methods to mitigate vibration in excess of relevant criteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Validity Assessment of Laboratory Shear Modulus Using In-Situ Seismic Piezocone Test Results

Seismic piezocone device (SCPTu) together with Resonant Column and Cyclic Triaxial test apparatus are employed to measure small strain shear modulus (G0) of carbonate sandy and clayey soils of southern coasts of Iran. A large area of southern regions of Iran is formed from clay, silt and sand. In this study, maximum shear modulus that is derived from both field (by seismic piezocone) and labora...

متن کامل

Evaluation of Seismic Behaviour of Ferrocement Elevated Water Tanks by Using Ambient Vibrations Tests

In this study a series of ambient vibration tests on the triple ferrocement elevated water tanks with 150 cubic meters volume, is carried out. In order to verify the dynamic characteristics of full, half-full and one full tanks (mass eccentric system), the different arrangements of sensors are used. The effects of base rotation are also considered in the tests. Natural frequencies and mode shap...

متن کامل

Evaluation of Seismic Behaviour of Ferrocement Elevated Water Tanks by Using Ambient Vibrations Tests

In this study a series of ambient vibration tests on the triple ferrocement elevated water tanks with 150 cubic meters volume, is carried out. In order to verify the dynamic characteristics of full, half-full and one full tanks (mass eccentric system), the different arrangements of sensors are used. The effects of base rotation are also considered in the tests. Natural frequencies and mode shap...

متن کامل

Spatial Seismic Excitations and Response Spectra

Formal extensions of the response spectrum method to include spatial seismic effects are reviewed. Two approaches are described in detail: the first based on random vibrations of a simple oscillator under two-component excitations, and the second analyzing multi-column building seismic response. The subjective choice of these two complementing approaches aims at analyzing the phenomenon of spat...

متن کامل

Probabilistic Seismic Hazard Assessment of Tehran Based on Arias Intensity

A probabilistic seismic hazard assessment in terms of Arias intensity is presented for the city of Tehran. Tehran is the capital and the most populated city of Iran. From economical, political and social points of view, Tehran is the most significant city of Iran. Many destructive earthquakes happened in Iran in the last centuries. Historical references indicate that the old city of Rey and the...