Magnetic Resonance Elastography of Polymer Gel Dosimetry Phantoms

نویسندگان

  • Y. Mariappan
  • S. L. Vieira
  • J. P. Fernandes
  • A. A. Carneiro
  • M. Fatemi
  • R. L. Ehman
چکیده

Introduction: Magnetic resonance imaging dependent polymer gel dosimetry is a technique that offers unique advantages for implementing increasingly complex radiotherapy procedures, due to the high spatial resolution and volumetric dosimetry capabilities. The technique involves the estimation of radiation dose distribution based on the changes in MR relaxation parameters caused by radiation induced polymerization (1). Magnetic Resonance Elastography (MRE) is a technique for quantitatively assessing the stiffness of materials by imaging the propagation of externally induced mechanical shear waves(2). Since radiation causes polymerization of monomers in polymer gel dosimeters, we hypothesized that the stiffness of an irradiated region would quantitatively reflect the radiation dose to the gel. The purpose of this work was to test this hypothesis in a series of polymer gel phantoms by investigating the correlation between the absorbed radiation dose and MREassessed stiffness. If the hypothesis is correct, this would provide an independent approach for polymer gel-based radiation dosimetry. Materials and Methods: A 1.5-T whole body scanner (GE Signa, Milwaukee, WI) was used in all of the experiments. A series of cubic phantoms of 236 cm were made using the MAGIC dosimetry gel (3) and were irradiated with a conventional 1.25 MeV Theratron 780C Cobalt-60 radiation therapy unit (MDS Nordion, Kanata, Canada). A cylindrical region (radius 3 cm) of the phantom was irradiated, with the phantom remaining stationary and the Co-60 unit gantry rotating (180) around the isocenter using parallel-opposed fields to guarantee dose distribution homogeneity. The radiation dose ranged from 0 to 50 Gy with 10 Gy steps. MR Relaxometry (4) images depicting the transverse relaxation parameter (R2 = 1/T2) of these irradiated phantoms were acquired with a double echo spin-echo sequence with echo times (TE) of 20 and 100 ms and a long repetition time (TR = 4,000 ms). For acquiring MRE data, mechanical shear waves of frequency 250 Hz were introduced in these phantoms and the propagation of these waves was imaged using a gradient echo based pulse sequence with one cyclic motion encoding gradient pair. Other relevant imaging parameters were FOV = 14 cm, acquisition matrix = 256x64, frequency encoding direction = SI, TR/TE = 100/21 ms and slice thickness = 10 mm. From these wave propagation images, elastograms were generated using a Local Frequency Estimation algorithm with application of spatio-temporal directional filters (5). Results and Discussion: Figure 1a shows a spin echo MR magnitude image of the 50 Gy absorbed dose phantom with TE at 20 ms, where the presence of the irradiated region could be identified due to the change in T2. It becomes clearly visible in the normalized relaxometry image of the phantom shown in figure 1b that maps the R2 of the phantom. Figure 2 shows one of the wave propagation images obtained from the elastography experiments for the control phantom with no irradiation (2a) and the 50 Gy absorbed dose phantom (2b). A wavelength difference between the 50 Gy and control phantoms is clearly apparent in the irradiated region. The wavelength is longer in the irradiated region than the non-irradiated region of the same phantom, due to increased stiffness in radiated gel. The corresponding elastograms for the control and the 50 Gy absorbed dose phantoms are shown in figures 3a and 3b respectively. It is evident that the stiffness of the irradiated region is higher than that of the non-irradiated region in the same sample or the control phantom due to the conversion of monomers to polymer aggregates upon irradiation. Comparing the stiffness estimate map and the normalized relaxometry map of the 50 Gy phantom (1b), it can be seen that they are very well correlated. Figure 4 shows the stiffness values of the phantoms as a function of the absorbed dose and the increase in stiffness of the irradiated region as the radiation dose increases is clearly evident. Conclusion: The results show that the stiffness of a polymer gel dosimeter is directly correlated to the applied radiation dose. Given this correlation, it is possible to use Magnetic Resonance Elastography to estimate radiation dose distribution through the measurement of shear stiffness of materials. We conclude that MRE provides an independent method for measuring radiation does distributions in polymer gel dosimetry constructs. The results provide motivation for further studies to compare the accuracy and dose estimation ranges of relaxometry and elastography-based 3D gel dosimetry methods. References :(1) Maryanski et al., Phys Med Biol. 39: 1437-1455, 1994. (2) Muthupillai et al., Science 269: 1854–1857 1995. (3) Fong et al., Phys Med Biol. 46: 3105–3113, 2001. (4)Carneiro et al., Braz J Phys 36: 9-15, 2006. (5) Manduca A et al., Med Imag Anal. 5: 237-254, 2001 Figure 1 : 1a. Conventional MR magnitude image and 1b. Normalized Relaxometry image of the 50 Gy phantom depicting R2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electron Beam Dosimetry in Heterogeneous Phantoms Using a MAGIC Normoxic Polymer Gel

Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...

متن کامل

Uncertainty Analysis in MRI-based Polymer Gel Dosimetry

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

متن کامل

Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.

A quantitative comparison of two full three-dimensional (3D) gel dosimetry techniques was assessed in a clinical setting: radiochromic gel dosimetry with an in-house developed optical laser CT scanner and polymer gel dosimetry with magnetic resonance imaging (MRI). To benchmark both gel dosimeters, they were exposed to a 6 MV photon beam and the depth dose was compared against a diamond detecto...

متن کامل

Mechanical and dose delivery accuracy evaluation in radiosurgery using polymer gels

The polymer gel-Magnetic Resonance Imaging (MRI) dosimetry technique was employed to evaluate the mechanical and dose delivery accuracy in Leksell gamma knife stereotactic radiosurgery for the treatment of multiple targets. Two different polymer gel dosimeter formulations that have been reported in the literature were prepared in-house. A plan for the treatment of four brain metastases (targets...

متن کامل

Brachytherapy polymer gel dosimetry with xCT

ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008