Integrity of craniofacial plating systems after multiple sterilization procedures.
نویسندگان
چکیده
PURPOSE To determine the effect of multiple autoclave sterilization cycles on the integrity of titanium plates and screws used in craniofacial reconstruction. MATERIALS AND METHODS Torque to fracture was evaluated for 36 titanium 6AL-4V (Ti 6/4) screws divided evenly into 3 groups and tested as machined (control), after 10 cycles of autoclaving or after 50 cycles of autoclaving. Sterilization was carried out by autoclaving for 15 minutes followed by 8 minutes of drying at 270 degrees to 272 degrees F. The maximum torque attained before fracture was recorded. Rotating beam specimens were crafted from single lots of Ti 6/4, commercially pure titanium grade 4 (CP4) and commercially pure titanium grade 2 (CP2), and then subjected to testing in a standard rotating beam device as machined (control), after 10 cycles of autoclaving or after 50 cycles of autoclaving. The cycles required to fracture the specimen at a given applied stress were recorded for each material and for the number of autoclavings carried out before testing. RESULTS Although there was a trend toward decreased strength and increased ability to fracture with increased number of autoclave cycles, this did not reach statistical significance. Torque to fracture testing for 7 mm Ti 6/4 screws showed no significant difference in the maximum torque reached before fracture between controls, those screws that had been autoclaved 10 times (P < .500 +/- 5.70) and those that had been autoclaved 50 times (P < .398 +/- 4.08). Rotating beam specimens of Ti 6/4, CP4, and CP2 showed no significant difference in cycles to fracture regardless of the number of sterilization cycles to which the material was subjected. CONCLUSIONS Repeated cycles of autoclaving had no significant effect on the integrity of titanium plates and screws routinely used in craniofacial surgery.
منابع مشابه
Comparison of tensile strength of resorbable plating systems used in monocortical mandible angle osteotomy repair.
OBJECTIVE To determine the usefulness of resorbable plating systems in load-bearing applications of the mandible and the location of critical failure. METHODS An osteotomy was created in 24 fresh cadaveric mandibles at the angle and fixated by the Champy technique with similar resorbable craniofacial plating systems from 4 manufacturers. Each mandible was held rigid as a material test system ...
متن کاملبررسی تطابق لبهای بین دو نوع رستوریشن زیرکونیایی Cercon و Zirkonzahn قبل و بعد از پرسلنگذاری
Background and Aims: The marginal integrity of fixed restorations always is a major matter of concern for dental clinicians. Any cause of distortion, including veneering processes, in the marginal integrity is supposed to be detrimental for long-term success of fixed dental prostheses. The aim of this in vitro study was to compare the marginal adaptation of two different full ceramic restoratio...
متن کاملBiomechanical Integrity of Human Allograft Bone After Sterilization
Musculoskeletal allografts have been used extensively for a variety of orthopaedic procedures. Allograft does have the potential, however, to transmit a variety of pathogens. Two current sterilization methods widely used in the tissue banking industry are ethylene oxide (ETO) treatment and gamma irradiation. ETO has been shown to adversely affect the biologic incorporation of allograft tissue. ...
متن کاملInfluence of Sterilization and Preservation Procedures on the Integrity of Serum Protein-Coated Magnetic Nanoparticles
Protein-coated magnetic nanoparticles are promising candidates for various medical applications. Prior to their application into a biological system, one has to guarantee that the particle dispersions are free from pathogens or any other microbiologic contamination. Furthermore, to find entrance into clinical routine, the nanoparticle dispersions have to be storable for several months. In this ...
متن کاملA biologic model for assessment of osseous strain patterns and plating systems in the human maxilla.
PURPOSE This study was conducted to examine a biomechanical model and to help answer fundamental questions that relate to rigid plate fixation in the maxilla. Specifically, we sought to elucidate the principal strain patterns generated in the maxilla secondary to masticatory forces as well as the amount of permanent deformational changes incurred due to these loading forces. MATERIALS AND MET...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons
دوره 65 5 شماره
صفحات -
تاریخ انتشار 2007