A review of MR physics: 3T versus 1.5T.

نویسندگان

  • Brian J Soher
  • Brian M Dale
  • Elmar M Merkle
چکیده

This article illustrates changes in the underlying physics concepts related to increasing the main magnetic field from 1.5T to 3T. The effects of these changes on tissue constants and practical hardware limitations is discussed as they affect scan time, quality, and contrast. Changes in susceptibility artifacts, chemical shift artifacts, and dielectric effects as a result of the increased field strength are also illustrated. Based on these fundamental considerations, an overall understanding of the benefits and constraints of signal-to-noise ratio and contrast-to-noise ratio changes between 1.5T and 3T MR systems is developed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal findings on brain fluid-attenuated inversion recovery MR images at 3T.

BACKGROUND AND PURPOSE Fluid attenuated inversion recovery (FLAIR) MR imaging of the brain has become a routine tool for assessing lesions in patients with suspected neurologic disorders. There is growing interest in 3T brain FLAIR MR imaging but little normative data are available. The purpose of this study was to evaluate the frequency and topography of cerebral hyperintensities seen with FLA...

متن کامل

Comparing 3T and 1.5T MRI for mapping hippocampal atrophy in the Alzheimer's Disease Neuroimaging Initiative.

BACKGROUND AND PURPOSE Prior MR imaging studies, primarily at 1.5T, established hippocampal atrophy as a biomarker for Alzheimer disease. 3T MR imaging offers a higher contrast and signal-to-noise ratio, yet distortions and intensity uniformity are harder to control. We applied our automated hippocampal segmentation technique to 1.5T and 3T MR imaging data, to determine whether hippocampal atro...

متن کامل

3T versus 1.5T MR angiography in peripheral arterial occlusive disease: an equivalence trial in comparison with digital subtraction angiography

Background Contrast-enhanced MR angiography (CE-MRA) has evolved into a reliable imaging technique for peripheral arterial occlusive disease (PAOD). Recent advances in MRI technology offer large homogeneous magnetic fields with comparable Field-of-Views at 3T and 1.5T, allowing visualization of the complete runoff vascular tree by single-injection 3-station (pelvic/thigh/calf) moving-table CE-M...

متن کامل

Variance components associated with long-echo-time MR spectroscopic imaging in human brain at 1.5T and 3T

OBJECT Magnetic resonance spectroscopic imaging (MRSI) is increasingly used in medicine and clinical research. Previous reliability studies have used small samples and focussed on limited aspects of variability; information regarding 1.5T versus 3T performance is lacking. The aim of the present work was to measure the inter-session, intra-session, inter-subject, within-brain and residual varian...

متن کامل

High-resolution 3D-constructive interference in steady-state MR imaging and 3D time-of-flight MR angiography in neurovascular compression: a comparison between 3T and 1.5T.

BACKGROUND AND PURPOSE High-resolution MR imaging is useful for diagnosis and preoperative planning in patients with NVC. Because high-field MR imaging promises higher SNR and resolution, the aim of this study was to determine the value of high-resolution 3D-CISS and 3D-TOF MRA at 3T compared with 1.5T in patients with NVC. MATERIALS AND METHODS Forty-seven patients with NVC, trigeminal neura...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging clinics of North America

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 2007