Effect of Femoral Stem Modular Neck’s Material on Metal Ion Release
نویسندگان
چکیده
Background In recent decades, the popularity of modular necks in total hip arthroplasty (THA) has increased since modular necks offer the potential to restore the patient's native anatomy, and thus improve stability. Unfortunately, modular necks are associated with higher complication rates, including implant fracture and modular junction corrosion with adverse local tissue reaction to metal debris. Objective The objective of this study was to determine the impact of modular neck material on titanium (Ti), chrome (Cr), and cobalt (Co) metal ion levels in patients who underwent a THA with Ti femoral stem, Ti or CrCo modular neck, and ceramic-on-ceramic (CoC) bearing. Methods Whole blood Ti, Cr, and Co levels were compared at a minimum 1-year follow-up in 36 patients who underwent unilateral, primary CoC large-diameter head THA with Profemur® Preserve modular femoral stems (MicroPort, Arlington, TX, USA). Results Higher Co concentrations were observed in the CrCo modular neck group (0.46 versus 0.26 µg/l in the Ti neck group, P=0.004) and higher Ti concentrations were observed in the Ti modular neck group (1.98 vs 1.59 µg/l in the CrCo neck group, P=0.007). However, these differences were not clinically meaningful since the absolute values remained within what is considered the safe range of Ti, Cr, and Co ions in whole blood. No patients were re-operated or revised. Conclusion Modular neck materials had an impact on whole blood metal ion levels but the concentrations measured remained within the safe range at 1-year follow-up. There were no indirect signs of modular junction corrosion with either CrCo or Ti femoral necks.
منابع مشابه
Fretting and Metal Release of Modular Neck Total Hip Arthroplasty
INTRODUCTION: In current total hip arthroplasty, modularity between the head-neck connection of the femoral stem is well established. More recently, implants with an additional modular connection between the neck and stem have become more popular. The ability to adjust the head centre relative to the stem axis intraoperatively, by connecting the neck in different positions, guarantees high vers...
متن کاملEarly corrosion-related failure of the rejuvenate modular total hip replacement.
BACKGROUND The Rejuvenate modular-neck stem implant (Stryker Orthopaedics, Mahwah, New Jersey) was recently recalled due to corrosion at the femoral neck-stem junction. The purpose of this study was to investigate the rate of corrosion-related failure and survivorship of this implant and analyze the correlation of implant and patient factors with serum metal ion levels and revisions. METHODS ...
متن کاملFretting and corrosion in modular-neck total hip arthroplasty femoral stems.
BACKGROUND During total hip arthroplasty, use of a modular femoral neck on a stemmed implant allows optimization of neck anteversion, length, and offset, resulting in more accurate balance. We performed a retrospective analysis of a consecutive cohort of patients who had undergone total hip arthroplasty with a modular-neck hip system with ceramic-on-ceramic bearings. METHODS We reviewed the r...
متن کاملDoes Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis
Due to their theoretical advantages, hip systems combining modular necks and large diameter femoral heads have gradually gained popularity. However, among others, concerns regarding changes in the load transfer patterns were raised. Recent stress analyses have indeed shown that the use of modular necks and big femoral heads causes significant changes in the strain distribution along the femur. ...
متن کاملAdverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.
BACKGROUND Femoral stems with dual-taper modularity were introduced to allow additional options for hip-center restoration independent of femoral fixation in total hip arthroplasty. Despite the increasing availability and use of these femoral stems, concerns exist about potential complications arising from the modular neck-body junction. METHODS This was a multicenter retrospective case serie...
متن کامل