Validation of X-ray fluorescence-measured Swine femur lead against atomic absorption spectrometry.
نویسندگان
چکیده
The aim of this study was to apply the technique of (109)Cd-based K-shell X-ray fluorescence (XRF) bone lead measurements to swine femurs and to validate the concentrations obtained therefrom against an independent chemical measurement of bone lead: atomic absorption spectrometry (AAS). The femurs ranged in lead concentration from 1.0 to 24.5 microg of lead per gram of ashed bone, as measured by AAS. On average, XRF overestimated AAS-measured femur lead by 2.6 microg/g [95% confidence interval (CI), 1.1-4.0 microg/g], approximately 2 microg/g poorer than that observed in studies of human tibiae. Measurements of swine femur and, by extension, of nonhuman bones may require adjustment of the XRF spectrum peak extraction method.
منابع مشابه
Determination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination
Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...
متن کاملAn interlaboratory comparison of bone lead measurements via K-shell X-ray fluorescence spectrometry: validation against inductively coupled plasma mass spectrometry.
(109)Cd-based K-shell X-ray fluorescence spectrometry (hereafter, for brevity, XRF) is used, often in epidemiological studies, to perform non-invasive, in vivo measurements of lead in bone. We conducted the first interlaboratory study of XRF via the circulation of nine goat tibiæ in which the mean lead value ranged from 4.0 µg g(-1) to 55.3 µg g(-1) bone mineral. The test tibiæ were subsequentl...
متن کاملTungsten coil devices in atomic spectrometry: absorption, fluorescence, and emission.
In this work, tungsten coil (W-Coil) devices are used as atomizers for electrothermal atomization atomic absorption spectrometry (ETAAS), electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS), and electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES). For most cases in ETAAS and ETA-LEAFS, limits of detection (LODs) usi...
متن کاملFluoride Precipitation of Cu Over Fe in a Selected pH Window
Fe is an impurity in most leach liquors. Its coexistence with copper in leaching solution of chalcopyrite (CuFeS2) which is the most important mineral of copper creates major extraction problems. Hydrochloric acid dissolves both copper and iron during chloride leaching of this mineral. Separation of Fe from Cu is thus necessary to obtain pure copper. This paper presents a novel metho...
متن کاملEvaluation of X-Ray Absorption by Ointment Containing Bismuth Oxide Nanoparticles in Radiology Staff
Introduction: The effects of X-rays on carcinogens have been proven in recent years. Today, lead is used in many devices such as lead covers, thyroid protectors to protect the body against x-rays. But this equipment contains many disadvantages such as, Toxicity, High weight and Lack of flexibility. Today, newer methods, such as semi-solid skin care products (cream, ointment), a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental Health Perspectives
دوره 109 شماره
صفحات -
تاریخ انتشار 2001