Beyond restenosis: five-year clinical outcomes from second-generation coronary stent trials.
نویسندگان
چکیده
BACKGROUND In the first year after coronary stent implantation, clinical failures are driven mainly by procedural complications and restenosis, but the subsequent relative contributions of restenosis and disease progression to late failures are less clear. METHODS AND RESULTS We observed 1228 patients for 5 years after the implantation of stents as part of pivotal second-generation coronary stent trials. Clinical events of death, myocardial infarction, repeat revascularization, and repeat hospitalization for acute coronary syndrome or congestive heart failure were attributed to the index stented (target) lesion or other distinct sites (either in the target or other coronary vessels) and further classified as procedural, restenosis, or nonrestenosis. During the first year the hazard rate was 18.3% for target-lesion events and 12.4% for events unrelated to the target lesion. After the first year the average annual hazard rate was 1.7% for target-lesion events and 6.3% for nontarget-lesion events. By the fifth year, restenosis events occurred in 20.3% of patients, whereas 30-day procedural complications or later nonrestenosis events occurred in 37.9%, including 11.4% who also experienced a restenosis event, for a combined cumulative event rate of 46.4%. Diabetes mellitus and multivessel disease were independently associated with increased risk for both restenosis and nonrestenosis events. CONCLUSIONS In a low-risk clinical trial population, the clinical outcome beyond 1 year after stenting is determined by a high rate of events related to disease progression in segments other than the stented lesion, which itself remains relatively stable.
منابع مشابه
Clinical Outcomes From The Bioresorbable Vascular Scaffold: Is There A Role for Them?
The risk of stent thrombosis and restenosis with the second generation drug eluting stents remains. The bioresorbable vascular scaffold is a third generation stent and overcomes the problems associated with drug eluting metallic stents. The bioresorbable vascular scaffold completely absorbs within the coronary vessel over 3-5 years. Multiple trials in patients with non complex coronary disease ...
متن کاملClinical restenosis after coronary stenting: perspectives from multicenter clinical trials.
OBJECTIVES We sought to evaluate clinical restenosis in a large population of patients who had undergone coronary stent placement. BACKGROUND One-year success after coronary stenting is limited mainly by restenosis of and requirement for repeat revascularization of the treated lesion. We studied 6,186 patients (6,219 lesions) pooled from several recently completed coronary stent trials. Clini...
متن کاملInterventional Cardiology Comparison of Everolimus-Eluting and Sirolimus-Eluting Coronary Stents 1-Year Outcomes from the Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial (RESET)
Background—Several recent randomized trials comparing everolimus-eluting stent (EES) and sirolimus-eluting stent (SES) reported similar outcomes. However, only 1 trial was powered for a clinical end point, and no trial was powered for evaluating target-lesion revascularization. Methods and Results—Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial is a prospective ...
متن کاملPeriprocedural and late consequences of overlapping Cypher sirolimus-eluting stents: pooled analysis of five clinical trials.
OBJECTIVES The purpose of this research was to determine the relative safety and efficacy of multiple (> or =2) overlapping Cypher sirolimus-eluting stents (SES) (Johnson & Johnson, New Brunswick, New Jersey). BACKGROUND Overlapping coronary stents are common. The periprocedural and late clinical and angiographic consequences of overlapped coronary stents are not clearly defined, particularly...
متن کاملUpdate on the everolimus-eluting coronary stent system: results and implications from the SPIRIT clinical trial program
Drug-eluting stents (DES) have had a major impact in interventional cardiology. Compared to bare metal stents, they significantly reduce restenosis and the need for target vessel revascularization. Four DES are available in the US, the first-generation sirolimus-eluting (Cypher((R))) and paclitaxel-eluting (Taxus((R))) stents and later approved second-generation everolimus-eluting (Xience V((R)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 110 10 شماره
صفحات -
تاریخ انتشار 2004