On the heating of small inductively coupled RF coils mounted on an intravascular model catheter during MR imaging

نویسندگان

  • H. Busse
  • G. Thörmer
  • N. Garnov
  • J. Haase
  • T. Kahn
  • M. Moche
چکیده

Introduction/Purpose Small inductively coupled RF coils have already been suggested or used as MR reference markers for various purposes, for example automatic patient registration, stereotactic planning, and visualization of devices inside the magnet [1-4]. Such markers may also be suitable for the guidance of intravascular devices (catheters) because they require no electrical connection to the scanner. On the downside, inductive coupling of these devices may lead to a considerable heating during RF-intense MR imaging which may pose a safety hazard [3,4]. Therefore, the goal of this work was to assess the heating behavior of a catheter-mounted, semi-active marker design under various experimental conditions in a vessel phantom.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel optically tunable capacitor for RF safe tuning and decoupling of intravascular MR coils

S. Weiss, T. Uelzen, G. Pantel, J. Mueller Philips Research Laboratories, Hamburg, Germany, Department of Micro Systems Technology, Hamburg University of Technology, Hamburg, Germany, MRI Devices Daum GmbH, Schwerin, Germany Objective: The motivation for the application of intravascular imaging coils is to gain high SNR images from a local area. To maximize SNR, proper tuning and matching of su...

متن کامل

Miniature Optical Signal Transmission System for an Active Intravascular Device

Objective: Active devices with wired receive coils enable very fast and robust catheter tracking and also intravascular imaging, but potential RF heating of such active devices has so far prevented their clinical use. Recently, a transformer-based cable was presented that efficiently reduces RF heating for active devices [1]. Similar results were obtained with an approach based on diodes [2]. W...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

RF-safe intravascular imaging using a self-visualizing transformer line

Objective: Intravascular MR-imaging may provide a local SNR gain possibly relevant for some interventional and diagnostic applications like high resolution intravascular imaging. However, regular signal transmission lines are not RF-safe due to possible RF heating of leads by resonant excitation of common mode currents. This safety issue prohibits intravascular MR imaging coils from being used ...

متن کامل

Simultaneous radiofrequency (RF) heating and magnetic resonance (MR) thermal mapping using an intravascular MR imaging/RF heating system.

Previous studies have confirmed the possibility of using an intravascular MR imaging guidewire (MRIG) as a heating source to enhance vascular gene transfection/expression. This motivated us to develop a new intravascular system that can perform MR imaging, radiofrequncy (RF) heating, and MR temperature monitoring simultaneously in an MR scanner. To validate this concept, a series of mathematica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009