Bacterial nitrification in chloraminated water supplies.

نویسنده

  • D A Cunliffe
چکیده

Nitrifying bacteria were detected in 64% of samples collected from five chloraminated water supplies in South Australia and in 20.7% of samples that contained more than 5.0 mg of monochloramine per liter. Laboratory experiments confirmed that nitrifying bacteria are relatively resistant to the disinfectant. Increased numbers of the bacteria were associated with accelerated decays of monochloramine within distribution systems. The combination of increased concentrations of oxidized nitrogen with decreased total chlorine residuals can be used as a rapid indicator of bacterial nitrification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ammonia- and nitrite-oxidizing bacterial communities in a pilot-scale chloraminated drinking water distribution system.

Nitrification in drinking water distribution systems is a common operational problem for many utilities that use chloramines for secondary disinfection. The diversity of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB) in the distribution systems of a pilot-scale chloraminated drinking water treatment system was characterized using terminal restriction fragment length polym...

متن کامل

Ammonia-oxidizing bacteria in a chloraminated distribution system: seasonal occurrence, distribution and disinfection resistance.

Nitrification in chloraminated drinking water can have a number of adverse effects on water quality, including a loss of total chlorine and ammonia-N and an increase in the concentration of heterotrophic plate count bacteria and nitrite. To understand how nitrification develops, a study was conducted to examine the factors that influence the occurrence of ammonia-oxidizing bacteria (AOB) in a c...

متن کامل

Monochloramine Microelectrode for In-Situ Application Within Chloraminated Distribution System Biofilm

A monochloramine microelectrode with a tip size between 5 and 15 μm and using platinum wire was successfully designed, fabricated and characterized for in-situ monochloramine measurement within chloraminated distribution system biofilm. The monochloramine microelectrode showed sensitivity toward monochloramine concentrations (0.54 to 16.1 mg Cl2/L) at an applied potential of +550 mV (Ag/AgCl re...

متن کامل

Occurrence of nitrifying bacteria and nitrification in Finnish drinking water distribution systems.

Microbiological nitrification process may lead to chemical, microbiological and technical problems in drinking water distribution systems. Nitrification activity is regulated by several physical, and chemical, and operational factors. However, the factors affecting nitrification in the distribution systems in boreal region, having its specific environmental characteristics, are poorly known. We...

متن کامل

Chloramination of Building Water Systems as an Alternative to Chlorination

1) Microbial control is inadequate 2) It results in higher proportions of Mycobacterium, Pseudomonas, Acinetobacter and nitrifying bacteria in biofilms 3) It induces the viable-but-nonculturable (VBNC) state in Legionella 4) Higher concentrations of nitrite and nitrate (regulated drinking water contaminants) can occur 5) It degrades to ammonium ion in premise plumbing treatments which can lead ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 57 11  شماره 

صفحات  -

تاریخ انتشار 1991