Quadricuspid aortic valve by transthoracic echocardiography.
نویسندگان
چکیده
A 55-year-old woman seeks medical attention with palpitations, atypical chest pain and dyspnea upon exertion, lasting for 12 months. ECG showed left ventricular hypertrophy. Transthoracic Doppler echocardiogram confirmed hypertrophy of the left chambers and showed a quadricuspid aortic valve, with equal-sized cusps, in addition to a moderate regurgitant central flow. Upon echocardiography, the quadricuspid valve is identified by its characteristic "X" form during diastole and rectangular aspect during systole. Heart failure symptoms are presumably caused by valve insufficiency due to abnormal leaflet coaptation. Considering the possibility of progressive regurgitation, follow up on the patient was performed with periodic echocardiographic control. Symptoms responded to treatment.
منابع مشابه
Quadricuspid Aortic Valve Visualized by Three-Dimensional Transthoracic Echocardiography
Quadricuspid aortic valve is a rare congenital anomaly that may cause aortic regurgitation. A 77-year-old male patient was referred to our clinic with complaints of stable angina pectoris. We report a case of a quadricuspid aortic valve diagnosed by 3-dimentional transthoracic echocardiography.
متن کاملQuadricuspid aortic valve by using intraoperative transesophageal echocardiography
Quadricuspid aortic valve is a rare congenital malformation of the aortic valve. Its diagnosis is often missed even with the use of transthoracic echocardiogram. Many of these patients progress to aortic incompetence later in life, hence requiring surgical intervention. In the case described in this report, a 61-year-old woman is presented with the features of congestive heart failure. The preo...
متن کاملQuadricuspid aortic valve diagnosed by transthoracic echocardiography in childhood.
Quadricuspid aortic valve is a rare congenital malformation of the heart leading to significant aortic regurgitation or stenosis. Its diagnosis by transthoracic echocardiography is difficult. Most of the cases are diagnosed during surgery or autopsy. Associated abnormalities of the coronary arteries should also be searched, since surgical injury may have devastating results. We herein present a...
متن کاملQuadricuspid aortic valve.
Quadricuspid aortic valve is a rare congenital heart defect usually detected by echocardiography or at the time of aortic valve surgery. Preoperative recognition of this abnormality has clinical significance because it is frequently associated with other congenital cardiac abnormalities and anomalies of coronary origin. We report a case of quadricuspid aortic valve, which was detected preoperat...
متن کاملQuadricuspid pulmonary valve identified by transthoracic echocardiography.
The quadricuspid pulmonary valve is a rare congenital anomaly. It tends to be clinically quiescent. Its diagnosis by two-dimensional echocardiography could be very difficult because of the anatomical features. We report on the echocardiographic findings of a 66-year-old female patient with mitral and aortic regurgitation of rheumatic origin and severe pulmonary hypertension. There was an aneuri...
متن کاملQuadricuspid aortic valve not discovered by transthoracic echocardiography
BACKGROUND Quadricuspid aortic valve is a rare congenital heart defect. Several different anatomical variations of a quadricuspid aortic valve has been described and aortic regurgitation is the predominant valvular dysfunction associated with quadricuspid aortic valve. CASE PRESENTATION A 68-year-old woman presented with almost a years history of increasing dyspnoea on exertion. The patient h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de cardiologia
دوره 91 2 شماره
صفحات -
تاریخ انتشار 2008