Effects of temperature on stability of blood homocysteine in collection tubes containing 3-deazaadenosine.

نویسندگان

  • Diane M Hill
  • Lisa J Johnson
  • Paul J Burns
  • Angela M Neale
  • Denise M Harmening
  • Andrew C Kenney
چکیده

BACKGROUND The accuracy of homocysteine (Hcy) results is currently compromised by the requirement to separate the plasma within 1 h of sample collection. We studied the effect of temperature on the stability of plasma Hcy over a 72-h time course in blood collected into evacuated tubes containing either EDTA alone or both EDTA and 3-deazaadenosine (3DA). METHODS We recruited 100 volunteers, including both diseased and healthy individuals with a range of baseline plasma Hcy values, from two centers. Blood samples were collected into tubes containing EDTA, and EDTA plus 3DA and stored at ambient temperature (20-25 degrees C) or refrigerated (2-8 degrees C). Aliquots of blood were centrifuged at various times up to 72 h, the plasma was removed, and Hcy was measured by HPLC. RESULTS Plasma Hcy measurement covering the sample collection and storage conditions during the whole time course was possible on samples from 59 of those recruited. One-way ANOVA for repeated measures within subjects revealed that only samples that were collected into tubes containing EDTA plus 3DA and stored refrigerated were stable over 72 h (P = 0.2761). CONCLUSIONS A combination of 3DA and storage at 2-8 degrees C will allow collection of samples for plasma Hcy measurement outside of the hospital setting and wider population screening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Addition of 3-deazaadenosine to vacutainer tubes stabilizes whole-blood homocysteine for at least 6 hours at ambient temperature.

To the Editor: Increased plasma homocysteine is now well established as a risk factor for cardiac, cerebral, and peripheral vascular disease (1). Despite this, the test is not widely available. This is partly because of practical difficulties in sample collection. The homocys-teine concentration increases in whole blood by up to 10% per hour unless samples are kept on ice and separated within 6...

متن کامل

Effects of storage temperature and time before centrifugation on ionized calcium in blood collected in plain vacutainer tubes and silicone-separator (SST) tubes.

We studied the stability of ionized calcium and pH in samples stored at either room temperature or 4 degrees C, in centrifuged and uncentrifuged blood-collection tubes and in centrifuged tubes containing a silicone-separator gel (SST tubes). At room temperature, in uncentrifuged blood from healthy individuals, mean ionized calcium usually increased no more than 10 mumol/L per hour; at 4 degrees...

متن کامل

Pharmacokinetics of the antiviral agent carbocyclic 3-deazaadenosine.

The pharmacokinetics of carbocyclic 3-deazaadenosine (Cc3Ado), a competitive inhibitor of S-adenosyl-L-homocysteine hydrolase and novel antiviral agent, was investigated in female BALB/c mice. Mice were dosed either orally or intravenously with a single dose of 10 mg/kg (10 microCi [3H]Cc3Ado), and blood and tissue samples were taken at selected intervals for 24 hr. The plasma concentration vs....

متن کامل

Blood Spot Homocysteine: A Feasibility and Stability

Homocystinuria is an autosomal recessive disorder usually caused by deficiency of cystathionine ␤-synthase, leading to grossly increased plasma and urine concentrations of homocysteine. There is considerable evidence that early detection and treatment can prevent the clinical consequences of the enzyme deficiency (1, 2); therefore, screening for the disorder has been advocated (1). Many cases o...

متن کامل

The Effect of Pre-Analytical Variability on the Measurement of MRM-MS-Based Mid- to High-Abundance Plasma Protein Biomarkers and a Panel of Cytokines

Blood sample processing and handling can have a significant impact on the stability and levels of proteins measured in biomarker studies. Such pre-analytical variability needs to be well understood in the context of the different proteomics platforms available for biomarker discovery and validation. In the present study we evaluated different types of blood collection tubes including the BD P10...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 48 11  شماره 

صفحات  -

تاریخ انتشار 2002