Multi-detector row CT urography: comparison of strategies for depicting the normal urinary collecting system.
نویسندگان
چکیده
PURPOSE To evaluate several protocols for depiction of the urinary collecting system with multi-detector row computed tomographic (CT) urography. MATERIALS AND METHODS Fifty-one patients with hematuria or a suspicious renal mass underwent CT urography, during which thinly collimated (1-mm) pyelographic phase scanning was performed 8-10 minutes after contrast medium administration. Patients were examined while prone only (n = 17) and while both prone and supine (n = 17) after a 250-mL infusion of normal saline. Each collecting system and ureter was divided into six segments that were assigned opacification scores. All acquisition techniques were compared, and the highest-scoring technique was compared with that in 17 patients who underwent conventional intravenous urography (IVU). Three reconstruction techniques (transverse, coronal, and maximal intensity projection) were also compared. Stratified analysis was performed with the paired two-tailed Student t test to compare opacification scores for both the acquisition techniques and display methods, both individually and in all possible combinations. RESULTS CT urography with supplemental saline administration, performed with the patient prone or supine, significantly improved mean opacification scores in the distal ureters (right, P =.004; left, P =.006). With this technique, CT urography produced a mean opacification score that was not significantly different from that with IVU in 11 of 12 segments and was significantly better than that with IVU in one of 12 segments (lower left ureter). Mean opacification scores obtained with transverse or coronal displays were equal to or higher than those obtained with maximum intensity projection reconstructions in all segments. CONCLUSION CT urography with a multi-detector row scanner and supplemental infusion of normal saline reliably displays the opacified urinary collecting system.
منابع مشابه
مقایسه یافتههای آنژیوگرافی عروق کلیوی به روش توموگرافی کامپیوتری چندلایه با یافتههای جراحی در افراد زنده دهنده کلیه
Background: In kidney transplantation decision about the proper kidney donation is different between surgeons, but simple vasculature anatomy and a kidney without abnormalities are the most important reasons of choosing a kidney. Therefore complete assessment of renal vessels of a live donor with noninvasive techniques is a necessity for nephrectomy. For delineation of the kidney vasculature...
متن کاملMulti-detector row CT urography in the evaluation of hematuria.
Hematuria can be well evaluated with a comprehensive contrast material-enhanced multi-detector row computed tomography (CT) protocol that combines unenhanced, nephrographic-phase, and excretory-phase imaging. Unenhanced images are obtained from the kidneys to the bladder and allow optimal detection of renal calculi, a common cause of hematuria. Renal parenchymal abnormalities, particularly mass...
متن کاملCT urography of a vesicourachal diverticulum containing calculi.
Urachal remnant disease is a relatively rare urological condition that presents a variety of clinical problems in adult patients. Contrast-enhanced multi-detector row computed tomography (MDCT) urography is a new diagnostic imaging technique providing comprehensive evaluation of the upper and lower urinary tract. MDCT urography performed with a combination of unenhanced, nephrographic phase, an...
متن کاملDiagnosis of Renal Arteriovenous Malformation using 64-row Multiple Detector Computed Tomography and Computed Tomography Angiography
Reprint requests to: Dr. Chen-Pin Chou Department of Radiology, Kaohsiung Veterans General Hospital. No. 386, Ta Chung 1st Road, Kaohsiung 813, Taiwan, R.O.C. A 47-year-old woman presented to our hospital with chief complaints of hematuria and left flank pain. The patient denied any recent history of trauma, renal surgery or urinary tract disease. Arterial-phase CT and three-dimensional CT angi...
متن کاملMultiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.
PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 225 3 شماره
صفحات -
تاریخ انتشار 2002