Effluent Guidelines Compliance
نویسندگان
چکیده
Ever-tightening regulations on releases to the environment have become a major business factor for the chemical industry. The Organic Chemicals, Plastics, and Synthetic Fibers (OCPSF) effluent guidelines have required many manufacturing sites to expand or upgrade their wastewater treatment plants ("P) at considerable cost. Du Pont has recognized the need to shift the emphasis from "end-of-pipe'' treatment to waste reduction and elimination at the process source. The Du Pont Belle, West Virginia plant is implementing a program to comply with the OCPSF effluent guidelines by reducing the organic waste load to the WWTP, with secondary emphasis on upgrading the facility for more efficient treatment. This program will reduce the WWTP load by 50%, control priority pollutants at their source and minimize future shock loads from nine processes. This approach will save over $7 million of the investment that would have been required if the effluent reductions were achieved only from WWTP modifications. BOD loads have been reduced to date by over 40% and forecast permit exceedances have dropped from 19 to 2 since 1987. Other anticipated benefits of the waste minimization program are reduced sludge production and volatile organic emissions, as well as greatly improved product yield in one process.
منابع مشابه
Treated Wastewater Effluent as a Source of Microbial Pollution of Surface Water Resources
Since 1990, more than 1.8 billion people have gained access to potable water and improved sanitation worldwide. Whilst this represents a vital step towards improving global health and well-being, accelerated population growth coupled with rapid urbanization has further strained existing water supplies. Whilst South Africa aims at spending 0.5% of its GDP on improving sanitation, additional fact...
متن کاملChapter 173-205 WAC WHOLE EFFLUENT TOXICITY TESTING AND LIMITS
WAC 173-205-010 Purpose. 173-205-020 Definitions. 173-205-030 Applicability. 173-205-040 Determining the need for effluent characterization. 173-205-050 Effluent testing for toxicity. 173-205-060 Additional effluent characterizations. 173-205-070 Monitoring for compliance with whole effluent toxicity limits. 173-205-080 Samples for whole effluent toxicity testing. 173-205-090 Response to noncom...
متن کاملCompliance With Infection Control Guidelines in the Operating Rooms
Introduction: Compliance with the safety standards in the operating rooms, as one of the most complex work environments in the health care systems, is very important. One of the safety measures is the infection control standard. Objective: This study aimed to investigate compliance with infection control standards in the operating rooms of teaching hospitals in Rasht City, Iran. Materials an...
متن کاملThe effect of wastewater effluent derived ligands on copper and zinc complexation
The shift toward bioavailability-based standards for metals such as copper and zinc not only improves the ecological relevance of the standard but also introduces significant complexity into assessing compliance. This study examined differences in the copper and zinc complexation characteristics of effluents from a range of different sewage treatment works and in relation to so-called 'natural'...
متن کاملRegulating Whole Effluent Toxicity Using “percent Effect” as the Test Endpoint
Traditionally, the No-Observed-Effect-Concentration (NOEC) or Inhibition Concentration (IC-25) are used to report the level of toxicity in effluent samples. These endpoints, and the methods used to calculate them, have several well known limitations that interfere with reasonable potential calculations, discharge limit development and permit compliance determinations. An alternative approach us...
متن کامل