Enhanced sensitivity in flow injection analysis using a long pathlength liquid waveguide capillary flow cell for spectrophotometric detection.
نویسنده
چکیده
Incorporation of a liquid waveguide capillary flow cell into a flow injection instrument enhances the sensitivity of flow injection analysis with spectrophotometric detection by two orders of magnitude. Nitrite determination at nM levels has been used to demonstrate the feasibility of this novel technique for trace analysis. Combining the long pathlength spectrophotometry with flow injection analysis, this technique has advantages of low detection limit, good precision and high sample throughput.
منابع مشابه
Spectrophotometric determination of zinc and copper in a multi-syringe flow injection analysis system using a liquid waveguide capillary cell: application to natural waters.
This work exploits a multi-syringe injection analysis (MSFIA) system coupled with a long liquid waveguide capillary cell for the spectrophotometric determination of zinc and copper in waters. A liquid waveguide capillary cell (1.0m pathlength, 550 μm i.d. and 250 μL internal volume) was used to enhance the sensitivity of the detection. The determination for both ions is based on a colorimetric ...
متن کاملA multi-syringe flow injection system for the spectrophotometric determination of trace levels of iron in waters using a liquid waveguide capillary cell and different chelating resins and reaction chemistries
A method integrating a long waveguide capillary cell with a preconcentration resin in a multi-syringe flow injection analysis (MSFIA) system for iron determination in waters was developed. The determination of iron is based on a colorimetric reaction and two reagents were tested, ferrozine and ammonium thiocyanate. A liquid waveguide capillary cell (1.0 m pathlength, 550 μm i.d. and 250 μL inte...
متن کاملRapid speciation of trace iron in rainwater by reverse flow injection analysis coupled to a long path length liquid waveguide capillary cell and spectrophotometric detection
A method for speciation and determination of low levels of dissolved iron in rainwater was established by coupling reverse flow injection analysis with a 2-m liquid waveguide capillary cell and spectrophotometric detection. Ferrozine solution was injected into a sample stream to form an Fe(II)-ferrozine complex with Fe(II), and the absorbance of this complex was detected at both 562 nm and 625 ...
متن کاملSequential injection trace determination of iron in natural waters using a long-pathlength liquid core waveguide and different spectrophotometric chemistries
We developed a sequential injection analysis (SIA) method for the determination of iron in coastal, ground, and surface fresh waters using two different reagents (ferrozine and 1,10-phenathroline). The methodology uses a double-line SIA system to improve mixing conditions between sample and reagent solutions. A liquid waveguide capillary cell (LWCC) with 1.0 m pathlength, 550 μm i.d., and 250 μ...
متن کاملLiquid core waveguide spectrophotometry for the sensitive determination of nitrite in river water samples.
A flow injection analysis system was built with a liquid core waveguide spectrophotometric detector using an 80 cm Teflon AF-1600 capillary tube (2,2-bistrifluoromethyl-4,5-difluoro-1,3-dioxole/tetrafluoroethylene). The system was applied to determine nitrite ion in river water samples. The lower limit of detection for nitrite was 2.1 nmol dm(-3) (0.1 ng dm(-3) as NO(2)(-)) and the relative sta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 22 1 شماره
صفحات -
تاریخ انتشار 2006