Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly.
نویسندگان
چکیده
OBJECTIVE After aortic valve replacement, the effects of a small functional prosthesis on the extent and pattern of regression of left ventricular hypertrophy and on clinical outcomes may be less significant in older patients with low cardiac output requirements. The objective of this study was therefore to determine whether patient-prosthesis mismatch affects left ventricular mass regression in the elderly. METHODS The population studied was made up of 88 patients over 65 years of age with pure aortic stenosis who underwent mechanical aortic valve replacement. The effective orifice area index was calculated for each patient on the basis of the projected prosthesis in vivo effective orifice area. It was considered a continuous variable and influence of its entire range of values on the extent of left ventricular mass regression was analyzed in a multivariate prediction model. RESULTS Even though, in the group with prosthesis-patient mismatch there was a trend for lower postoperative left ventricular mass index (115+/-24 g/m(2) vs 102+/-27 g/m(2), p=0.24) and postoperative peak trans-prosthetic gradients (32+/-9.8 mmHg vs 28.9+/-7.79 mmHg, p=0.35) these differences were not statistically significant. The prevalence of residual left ventricular hypertrophy at follow-up was 50% in the group with patient-prosthesis mismatch and 50% in the group without patient-prosthesis mismatch (p=0.83). In multivariate analysis the only factors associated with indexed left ventricular mass were the follow-up time (p=0.015, r(2)=0.22) and preoperative indexed left ventricular mass (p=0.0012, r(2)=0.11). CONCLUSIONS The major finding of our study is that patient-prosthesis mismatch does not affect left ventricular mass regression in patients older than 65 with pure aortic stenosis who underwent mechanical aortic valve replacement. In older patients with low cardiac output requirements, even a small change in the valve effective orifice area after aortic valve replacement with modern efficient mechanical prosthesis, will result in a marked reduction of pressure gradient and this will be associated with a significant regression of left ventricular mass.
منابع مشابه
Predictors of Left Ventricular Mass Regression Following Aortic Valve Replacement
Method Randomized selection of 100 patients, underwent aortic valve replacement with a single type of bio-prosthesis (Medtronic Mosaic) for pure aortic stenosis. The study population showed that, 25/100 (25%) patients had prosthesis-patient mismatch of a moderate degree (indexed effective orifice area (IEOA) from 0.65 cm2/m2 0.85 cm2/m2). The effect of prosthesis-patient mismatch on the postope...
متن کاملHaemodynamics and left ventricular mass regression: a comparison of the stentless, stented and mechanical aortic valve replacement.
OBJECTIVE Our objective was to compare the degree of change in hemodynamics and left ventricular mass (LVM) regression after aortic valve replacement (AVR) with stentless, stented and mechanical valves. METHODS Patients greater than 59 years of age had AVR for aortic stenosis with the stentless xenograft (Cryolife-O'Brien, CLOB), stented xenograft (Carpentier-Edwards, C-E) or mechanical valve...
متن کاملPerformance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial.
OBJECTIVES Although stentless aortic bioprostheses are believed to offer improved outcomes, benefits remain unsubstantiated. The aim of our study was to compare stentless with stented bioprostheses, with regard to postoperative changes in left ventricular mass and hemodynamic performance, in the elderly patient. METHODS Forty patients with aortic stenoses, over the age of 75 years, were rando...
متن کاملFactors affecting left ventricular remodeling after valve replacement for aortic stenosis. An overview
Although a small percentage of patients with critical aortic stenosis do not develop left ventricle hypertrophy, increased ventricular mass is widely observed in conditions of increased afterload. There is growing epidemiological evidence that hypertrophy is associated with excess cardiac mortality and morbidity not only in patients with arterial hypertension, but also in those undergoing aorti...
متن کاملDefining patient-prosthesis mismatch and its effect on survival in patients with impaired ejection fraction.
BACKGROUND How best to define patient-prosthesis mismatch (PPM) continues to be debated. Over time, the indexed effective orifice area has become the most widely used method. However, the clinical relevance of PPM remains controversial. METHODS The indexed geometric orifice area and indexed effective orifice area were calculated for 143 patients having undergone aortic valve replacement with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2006