A biomechanical comparison of volar locked plating of intra-articular distal radius fractures: use of 4 versus 7 screws for distal fixation.

نویسندگان

  • David P Moss
  • Kenneth R Means
  • Brent G Parks
  • Christopher L Forthman
چکیده

PURPOSE To determine whether the number of distal locking screws significantly affects stability of a cadaveric simulated distal radius fracture fixed with a volar locking plate. METHODS We created AO/ASIF type C2 fractures in 10 matched pairs of human fresh-frozen cadaveric wrists and then fixed them using volar locking plates. The number of distal locking screws used was 4 screws or 7 screws in each wrist of the matched pair. We loaded the stabilized fractures cyclically to simulate 6 weeks of postoperative stressing during a therapy protocol and then loaded them to failure. Failure was defined as 2 mm or more of displacement of any fracture fragment as recorded by differential variable reluctance transducers. RESULTS No wrists failed during the cyclic loading portion for either the 4- or 7-screw construct. The average initial stiffness of the 7-screw construct was 69 N/mm (± 38) versus 48 N/mm (± 14) for the 4-screw construct. The average failure load for the 7-screw construct was 139 N (± 78) versus 108 N (± 18) for the 4-screw construct. Neither of these differences was statistically significant. CONCLUSIONS Although there was a trend toward increased initial stiffness and higher failure load in fractures fixed distally with 7 locking screws, the results were not statistically significant compared with fractures fixed with only 4 screws. Both constructs can withstand forces likely encountered in early therapy protocols. CLINICAL RELEVANCE The use of extra distal locking screws when fixing distal radius fractures increases expense and may increase the risk of complications, such as extensor tendon irritation or rupture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model

BACKGROUND The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In this study, we evaluated the stability of the volar plating system fixation with or without the rad...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year

BACKGROUND AND PURPOSE Promising results have been reported after volar locked plating of unstable dorsally displaced distal radius fractures. We investigated whether volar locked plating results in better patient-perceived, objective functional and radiographic outcomes compared to the less invasive external fixation. PATIENTS AND METHODS 63 patients under 70 years of age, with an unstable e...

متن کامل

CASE REPORT Union of an intra-articular distal radius fracture after successive failures of three locking plates: a case report

We report a case of a 30-year old male, who presented with a right distal radius intra-articular fracture complicated by compartment syndrome. He was treated with fasciotomies and fracture fixation with a 3.5 mm LCP (Synthes TM ), followed 7 days later by skin graft. Repeat radiographs 8 weeks later showed a break across the plate at the level of an unfilled screw hole over the fracture. He und...

متن کامل

Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction

BACKGROUND Distal radius fractures are common. The increasing prevalence of osteoporosis contributes to frequently complex articular injuries sustained even after low energy falls. The best method of treating complex type C distal radius fractures is debated. Locked volar plating and external fixation are both widely used with good reported results. Measures of success are traditionally based o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hand surgery

دوره 36 12  شماره 

صفحات  -

تاریخ انتشار 2011