Real-ECG extraction and stroke volume from MR-Compatible 12-lead ECGs; testing during stress, in PVC and in AF patients

نویسندگان

  • Zion Tsz Ho Tse
  • Charles L Dumoulin
  • Gari Clifford
  • Michael Jerosch-Herold
  • Daniel Kacher
  • Raymond Kwong
  • William Gregory Stevenson
  • Ehud Jeruham Schmidt
چکیده

Background Due to the Magneto-Hydro-Dynamic (MHD) effect, blood flow within the MRI’s magnetic field (B0) produces a large voltage during the S-T cardiac segment [1]. The peak MHD voltage (VMHD) can be comparable, in higher-field MRIs, to the R-wave amplitude of the real Electrocardiogram (ECGreal), so that VMHD reduces ECG-gating reliability and prevents ischemia-monitoring during cardiac imaging/interventions. We hypothesized that (1) separation of ECGreal and VMHD from 12-lead ECGs acquired within a 1.5T MRI could be achieved, using adaptive filtering, based on a set of ECG calibration measurements, and (2) a non-invasive beat-to-beat stroke-volume estimation could be achieved from time-integrated systolic VMHD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mobile phones in cryptogenic strOke patients Bringing sIngle Lead ECGs for Atrial Fibrillation detection (MOBILE-AF): study protocol for a randomised controlled trial

BACKGROUND Recently published randomised clinical trials indicate that prolonged electrocardiom (ECG) monitoring might enhance the detection of paroxysmal atrial fibrillation (AF) in cryptogenic stroke or transient ischaemic attack (TIA) patients. A device that might be suitable for prolonged ECG monitoring is a smartphone-compatible ECG device (Kardia Mobile, Alivecor, San Francisco, CA, USA) ...

متن کامل

Serial electrocardiographic assessments significantly improve detection of atrial fibrillation 2.6-fold in patients with acute stroke.

BACKGROUND AND PURPOSE Previous studies have reported a low, approximately 1% to 3%, rate of detection of occult atrial fibrillation (AF) with Holter monitor in patients with acute stroke. Furthermore, at least one study has reported that Holter monitoring could not always corroborate initial electrocardiographic (ECG) detection of AF suggesting underestimation of AF by Holter. We compare the d...

متن کامل

Continuous Rapid Quantification of Stroke Volume Using Magnetohydrodynamic Voltages in 3T Magnetic Resonance Imaging.

BACKGROUND To develop a technique to noninvasively estimate stroke volume in real time during magnetic resonance imaging (MRI)-guided procedures, based on induced magnetohydrodynamic voltages (VMHD) that occur in ECG recordings during MRI exams, leaving the MRI scanner free to perform other imaging tasks. Because of the relationship between blood flow (BF) and VMHD, we hypothesized that a metho...

متن کامل

Improved cardiac gating at 3T with the “3D-QRS” method utilizing MRI-compatible 12-lead ECGs

Background Blood is rapidly ejected from the left ventricle during early systole, travels in the aortic arch perpendicular to the MRI’s main field, thus generating a Magnetohydrodynamic (MHD) voltage which is larger than the real ECG QRS complex in high field MRI. The MHD voltage (VMHD) is severally irregular in patients with arrhythmia, since arrhythmic ECG beats are interleaved between succes...

متن کامل

Heart Rate Variability Classification using Support Vector Machine and Genetic Algorithm

Background: Electrocardiogram (ECG) is defined as an electrical signal, which represents cardiac activity. Heart rate variability (HRV) as the variation of interval between two consecutive heartbeats represents the balance between the sympathetic and parasympathetic branches of the autonomic nervous system.Objective: In this study, we aimed to evaluate the efficiency of discrete wavelet transfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2011