Light-adjustable lens.
نویسنده
چکیده
PURPOSE First, to determine whether a silicone light-adjustable intraocular lens (IOL) can be fabricated and adjusted precisely with a light delivery device (LDD). Second, to determine the biocompatibility of an adjustable IOL and whether the lens can be adjusted precisely in vivo. METHODS After fabrication of a light-adjustable silicone formulation, IOLs were made and tested in vitro for cytotoxicity, leaching, precision of adjustment, optical quality after adjustment, and mechanical properties. Light-adjustable IOLs were then tested in vivo for biocompatibility and precision of adjustment in a rabbit model. In collaboration with Zeiss-Meditec, a digital LDD was developed and tested to correct for higher-order aberrations in light-adjustable IOLs. RESULTS The results establish that a biocompatible silicone IOL can be fabricated and adjusted using safe levels of light. There was no evidence of cytotoxicity or leaching. Testing of mechanical properties revealed no significant differences from commercial controls. Implantation of light-adjustable lenses in rabbits demonstrated- excellent biocompatibility after 6 months, comparable to a commercially available IOL. In vivo spherical (hyperopic and myopic) adjustment in rabbits was achieved using an analog light delivery system. The digital light delivery system was tested and achieved correction of higher-order aberrations. CONCLUSION A silicone light-adjustable IOL and LDD have been developed to enable postoperative, noninvasive adjustment of lens power. The ability to correct higher-order aberrations in these materials has broad potential applicability for optimization of vision in patients undergoing cataract and refractive surgery.
منابع مشابه
Light-adjustable intraocular lens in post-LASIK and post-traumatic cataract patient.
The case illustrates the use of a light-adjustable intraocular lens (IOL) in a patient who had had refractive surgery and developed blunt trauma with resultant flap damage and traumatic cataract. Consistent with early reports of the light adjustable IOL, which show positive results in non-LASIK eyes, this case suggests that the light-adjustable IOL may have similar benefits in the post-LASIK ey...
متن کاملCorrection of residual hyperopia after cataract surgery using the light adjustable intraocular lens technology.
PURPOSE To determine whether residual hyperopia could be corrected postoperatively using the light adjustable lens technology in patients undergoing cataract surgery and light adjustable lens implantation. DESIGN Prospective, nonrandomized clinical trial. METHODS Fourteen eyes of 14 patients were studied. The manifest refraction, uncorrected visual acuity (UCVA), and best-corrected visual a...
متن کامل3D fluidic lens shaping--a multiconvex hydrodynamically adjustable optofluidic microlens.
Novel optical techniques for sensitive and reproducible fluorescence single cell analysis utilizing setups without single photon counting units are attractive for enhanced low-cost cell parameter screening. In this contribution we present the first microfluidic planar device to form an optofluidic adjustable convex lens with three-dimensional light focusing ability to improve optical sensor sys...
متن کاملRefractive accuracy with light-adjustable intraocular lenses.
PURPOSE To evaluate efficacy, predictability, and stability of refractive treatments using light-adjustable intraocular lenses (IOLs). SETTING University Hospital Virgen de la Arrixaca, Murcia, Spain. DESIGN Prospective nonrandomized clinical trial. METHODS Eyes with a light-adjustable IOL (LAL) were treated with spatial intensity profiles to correct refractive errors. The effective chang...
متن کاملGeneration of adjustable partially coherent bottle beams by use of an axicon-lens system.
We report, what is to our knowledge, the first experimental realization of partially coherent bottle beams. It is shown that partially coherent bottle beams can be achieved by the focusing of partially coherent light with an axicon-lens system. The influence of the spatial coherence of the incident partially coherent light and other parameters, such as the radius of the limiting aperture of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Transactions of the American Ophthalmological Society
دوره 101 شماره
صفحات -
تاریخ انتشار 2003