Differences in alarm events between disposable and reusable electrocardiography lead wires.
نویسندگان
چکیده
BACKGROUND Disposable electrocardiographic lead wires (ECG-LWs) may not be as durable as reusable ones. OBJECTIVE To examine differences in alarm events between disposable and reusable ECG-LWs. METHOD Two cardiac telemetry units were randomized to reusable ECG-LWs, and 2 units alternated between disposable and reusable ECG-LWs for 4 months. A remote monitoring team, blinded to ECG-LW type, assessed frequency and type of alarm events by using total counts and rates per 100 patient days. Event rates were compared by using generalized linear mixed-effect models for differences and noninferiority between wire types. RESULTS In 1611 patients and 9385.5 patient days of ECG monitoring, patient characteristics were similar between groups. Rates of alarms for no telemetry, leads fail, or leads off were lower in disposable ECG-LWs (adjusted relative risk [95% CI], 0.71 [0.53-0.96]; noninferiority P < .001; superiority P = .03) and monitoring (artifact) alarms were significantly noninferior (adjusted relative risk [95% CI]: 0.88, [0.62-1.24], P = .02; superiority P = .44). No between-group differences existed in false or true crisis alarms. Disposable ECG-LWs were noninferior to reusable ECG-LWs for all false-alarm events (N [rate per 100 patient days], disposable 2029 [79.1] vs reusable 6673 [97.9]; adjusted relative risk [95% CI]: 0.81 [0.63-1.06], P = .002; superiority P = .12.) CONCLUSIONS Disposable ECG-LWs with patented push-button design had superior performance in reducing alarms created by no telemetry, leads fail, or leads off and significant noninferiority in all false-alarm rates compared with reusable ECG-LWs. Fewer ECG alarms may save nurses time, decrease alarm fatigue, and improve patient safety.
منابع مشابه
Differences in Alarm Events between Disposable And
Background Disposable electrocardiographic lead wires (ECG-LWs) may not be as durable as reusable ones. Objective To examine differences in alarm events between disposable and reusable ECG-LWs. Method Two cardiac telemetry units were randomized to reusable ECG-LWs, and 2 units alternated between disposable and reusable ECG-LWs for 4 months. A remote monitoring team, blinded to ECG-LW type, asse...
متن کاملInfection rates in intensive care units by electrocardiographic lead wire type: disposable vs reusable.
BACKGROUND It is unknown if disposable electrocardiographic lead wires (ECG-LWs) reduce infection rates compared with cleaned, reusable lead wires. PURPOSE To compare infection rates in intensive care unit (ICU) patients receiving disposable versus reusable ECG-LWs. METHODS Matched adult ICUs were randomly assigned to disposable or reusable ECG-LWs. Outcomes were bloodstream infection, vent...
متن کاملThe not-so-hidden costs of surgical site infections.
Surgical site infections (SSIs) adversely affect approximately 500,000 patients annually, causing immense human suffering and taking a huge financial toll on patients, hospitals, insurance companies, and the government. National organizations have made recommendations for reducing SSIs, and many advances have been made in evidence-based practice recommendations that result in fewer SSIs. Reusab...
متن کاملMicrobial contamination of manually reprocessed, ready to use ECG lead wire in intensive care units
BACKGROUND A number of studies have shown that non-critical medical devices can be contaminated with pathogens, including those resistant to antibiotics and thus become a potential vector for transmission. Electrocardiography (ECG) lead wire are non-critical medical device which are always attached on patient skin during their stay in intensive care unit (ICU). In view of the patient's critical...
متن کاملStop the Noise: A Quality Improvement Project to Decrease Electrocardiographic Nuisance Alarms.
BACKGROUND As many as 99% of alarm signals may not need any intervention and can result in patients' deaths. Alarm management is now a Joint Commission National Patient Safety Goal. OBJECTIVES To reduce the number of nuisance electrocardiographic alarm signals in adult patients on the medical cardiovascular care unit. METHODS A quality improvement process was used that included eliminating ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of critical care : an official publication, American Association of Critical-Care Nurses
دوره 24 1 شماره
صفحات -
تاریخ انتشار 2015