Monitoring of Escherichia coli O157:H7 in food samples using lectin based surface plasmon resonance biosensor.
نویسندگان
چکیده
A novel surface plasmon resonance (SPR) biosensor using lectin as bioreceptor was developed for the rapid detection of Escherichia coli (E. coli) O157:H7. The selective interaction of lectins with carbohydrate components from bacterial cells surface was used as the recognition principle for the detection. Five types of lectins from Triticum vulgaris, Canavailia ensiformis, Ulex europaeus, Arachis hypogaea, and Maackia amurensis, were employed to evaluate the selectivity of the approach for binding E. coli O157:H7 effectively. A detection limit of 3×10(3) cfu mL(-1) was obtained for determination of E. coli O157:H7 when used the lectin from T. vulgaris as the binding molecule. Furthermore, the proposed biosensor was used to detect E. coli O157:H7 in real food samples. Results showed that the lectin based SPR biosensor was sensitive, reliable and effective for detection of E. coli O157:H7, which hold a great promise in food safety analysis.
منابع مشابه
Subtractive Inhibition Assay for the Detection of E. coli O157:H7 Using Surface Plasmon Resonance
A surface plasmon resonance (SPR) immunosensor was developed for the detection of E. coli O157:H7 by means of a new subtractive inhibition assay. In the subtractive inhibition assay, E. coli O157:H7 cells and goat polyclonal antibodies for E. coli O157:H7 were incubated for a short of time, and then the E. coli O157:H7 cells which bound antibodies were removed by a stepwise centrifugation proce...
متن کاملThe Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7
The purpose of this study was to develop a portable surface plasmon resonance (SPR) bioanalyzer for the sensitive detection of Escherichia coli O157:H7 in comparison with an enzyme-linked immunosorbent assay (ELISA). The experimental setup mainly consisted of an integrated biosensor and a homemade microfluidic cell with a three-way solenoid valve. In order to detect Escherichia coli O157:H7 usi...
متن کاملElectrochemical Impedance Immunosensor Based on Self-Assembled Monolayers for Rapid Detection of Escherichia coli O157:H7 with Signal Amplification Using Lectin
Escherichia coli O157:H7 is a predominant foodborne pathogen with severe pathogenicity, leading to increasing attention given to rapid and sensitive detection. Herein, we propose an impedance biosensor using new kinds of screen-printed interdigitated microelectrodes (SPIMs) and wheat germ agglutinin (WGA) for signal amplification to detect E. coli O157:H7 with high sensitivity and time-efficien...
متن کاملB cells Using Calcium Signaling for Specific and Rapid Detection of Escherichia coli O157:H7
A rapid and sensitive detection technology is highly desirable for specific detection of E. coli O157:H7, one of the leading bacterial pathogens causing foodborne illness. In this study, we reported the rapid detection of E. coli O157:H7 by using calcium signaling of the B cell upon cellular membrane anchors anti-E. coli O157:H7 IgM. The binding of E. coli O157:H7 to the IgM on B cell surface a...
متن کاملThe prevalence of Escherichia coli O157:H7, Listeria monocytogenes and Campylobacter spp. on bovine carcasses in Isfahan, Iran
This study was carried out to determine the prevalence of foodborne pathogens, Escherichia coli, E. coli O157:H7, Listeria monocytogenes and Campylobacter spp. on slaughtered cattle in Isfahan, Iran. A total of 203 cattle carcasses were sampled by surface section of neck meat taken immediately after slaughter and analyzed using microbiological examinations. Suspected colonies to E. coli O157:H7...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Food chemistry
دوره 136 3-4 شماره
صفحات -
تاریخ انتشار 2013