Relaxivity of Gd-based contrast agents on X nuclei with long intrinsic relaxation times in aqueous solutions.
نویسندگان
چکیده
The relaxivity of commercially available gadolinium (Gd)-based contrast agents was studied for X-nuclei resonances with long intrinsic relaxation times ranging from 6 s to several hundred seconds. Omniscan in pure 13C formic acid had a relaxivity of 2.9 mM(-1) s(-1), whereas its relaxivity on glutamate C1 and C5 in aqueous solution was approximately 0.5 mM(-1) s(-1). Both relaxivities allow the preparation of solutions with a predetermined short T1 and suggest that in vitro substantial sensitivity gains in their measurement can be achieved. 6Li has a long intrinsic relaxation time, on the order of several minutes, which was strongly affected by the contrast agents. Relaxivity ranged from approximately 0.1 mM(-1) s(-1) for Omniscan to 0.3 for Magnevist, whereas the relaxivity of Gd-DOTP was at 11 mM(-1) s(-1), which is two orders of magnitude higher. Overall, these experiments suggest that the presence of 0.1- to 10-microM contrast agents should be detectable, provided sufficient sensitivity is available, such as that afforded by hyperpolarization, recently introduced to in vivo imaging.
منابع مشابه
Magnetic Resonance Im Relaxivity of Gd-based contrast agents on X nuclei with long intrinsic relaxation times in aqueous solutions
The relaxivity of commercially available gadolinium (Gd)-based contrast agents was studied for X-nuclei resonances with long intrinsic relaxation times ranging from 6 s to several hundred seconds. Omniscan in pure C formic acid had a relaxivity of 2.9 mM 1 s , whereas its relaxivity on glutamate C1 and C5 in aqueous solution was ~0.5 mM 1 s . Both relaxivities allow the preparation of solutions...
متن کاملSynthesis and Application of New Gadolinium-Porphyrins as Potential MR Imaging Contrast Agents for Cancer Detection in Nude Mice
Two new potential magnetic resonance imaging contrast agents, Gd-hematoporphyrin (Gd-H) and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd TCP), were synthesized and applied to nude mice with human melanoma (MM 138) xenografts. These agents showed a high relaxivity because of their greater potential to coordinate water molecules. The reduction of T1 relaxation times of 16 and 21% was observed i...
متن کاملGadolinium-Diethylenetriaminepenta-Acetic acid Conjugated with Monoclonal Antibody C595 as New Magnetic Resonance Imaging Contrast Agents for Breast Cancer (MCF-7) Detection
Background: The monoclonal antibody, C595, against breast cancer cell line was conjugated with cyclic anhydride gadolinium-diethylenetriaminepenta-acetic acid (Gd-cDTPAa) to produce Gd-DTPA-C595 and used as specific breast cancer cell line (MCF-7) contrast agents in magnetic resonance imaging (MRI). Methods: After incubation of breast cancer cell line (MCF-7), with different contrast agents (G...
متن کاملComposite MR contrast agents for conditional cell-labeling
Gadolinium-chelates (Gd-DTPA) and superparamagnetic particles of iron oxide (SPIO) are two commonly used MR contrast agents that exhibit inherently different relaxation properties. These two agents have been used to label cells ex-vivo to generate signal contrast with respect to background tissue when introduced to a tissue-of-interest. Assuming minimal mutual interaction between these two agen...
متن کاملA New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite
Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 25 6 شماره
صفحات -
تاریخ انتشار 2007