Noise Maps for Quantitative and Clinical Severity Towards Long-Term ECG Monitoring

نویسندگان

  • Estrella Everss-Villalba
  • Francisco Manuel Melgarejo-Meseguer
  • Manuel Blanco-Velasco
  • Francisco Javier Gimeno-Blanes
  • Salvador Sala-Pla
  • José Luis Rojo-Álvarez
  • Arcadio García-Alberola
چکیده

Noise and artifacts are inherent contaminating components and are particularly present in Holter electrocardiogram (ECG) monitoring. The presence of noise is even more significant in long-term monitoring (LTM) recordings, as these are collected for several days in patients following their daily activities; hence, strong artifact components can temporarily impair the clinical measurements from the LTM recordings. Traditionally, the noise presence has been dealt with as a problem of non-desirable component removal by means of several quantitative signal metrics such as the signal-to-noise ratio (SNR), but current systems do not provide any information about the true impact of noise on the ECG clinical evaluation. As a first step towards an alternative to classical approaches, this work assesses the ECG quality under the assumption that an ECG has good quality when it is clinically interpretable. Therefore, our hypotheses are that it is possible (a) to create a clinical severity score for the effect of the noise on the ECG, (b) to characterize its consistency in terms of its temporal and statistical distribution, and (c) to use it for signal quality evaluation in LTM scenarios. For this purpose, a database of external event recorder (EER) signals is assembled and labeled from a clinical point of view for its use as the gold standard of noise severity categorization. These devices are assumed to capture those signal segments more prone to be corrupted with noise during long-term periods. Then, the ECG noise is characterized through the comparison of these clinical severity criteria with conventional quantitative metrics taken from traditional noise-removal approaches, and noise maps are proposed as a novel representation tool to achieve this comparison. Our results showed that neither of the benchmarked quantitative noise measurement criteria represent an accurate enough estimation of the clinical severity of the noise. A case study of long-term ECG is reported, showing the statistical and temporal correspondences and properties with respect to EER signals used to create the gold standard for clinical noise. The proposed noise maps, together with the statistical consistency of the characterization of the noise clinical severity, paves the way towards forthcoming systems providing us with noise maps of the noise clinical severity, allowing the user to process different ECG segments with different techniques and in terms of different measured clinical parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

“Short Paper” The Effect of Short Term and Long Term Feeding of Barley Seed with or Without eCG on Reproductive Performance of Goat During Breeding and Out Breeding Seasons

Nutritional and hormonal programs are one of the important ways of improving goat reproductive performance. Therefore, the present study was conducted to investigate the effect of using barley seed and eCG at the same time on the reproductive performance of goat in nomadic breeding conditions. The number of 60 goats of two to three-year-old in the breeding season and 60 goats of three to four-y...

متن کامل

Arm and wrist surface potential mapping for wearable ECG rhythm recording devices: a pilot clinical study

This study addresses an important question in the development of a ECG device that enables long term monitoring of cardiac rhythm. This device would utilise edge sensor technologies for dry, non-irritant skin contact suitable for distal limb application and would be supported by embedded ECG denoising processes. Contemporary ECG databases including those provided by MIT-BIH and Physionet are fo...

متن کامل

Implementation of Extended Kalman Filter for Real-Time Noncontact ECG Signal Acquisition in Android-Based Mobile Monitoring System

Noncontact electrocardiogram (ECG) measurement using capacitive-coupled technique is a very reliable long-term noninvasive health-care remote monitoring system. It can be used continuously without interrupting the daily activities of the user and is one of the most promising developments in health-care technology. However, ECG signal is a very small electric signal. A robust system is needed to...

متن کامل

Belt-type Wireless and Non-contact Electrocardiogram Monitoring System Using Flexible Active Electrode

Electrocardiogram (ECG) measurement using capacitively coupled electrode is a well-know method to get the ECG signal without direct skin-contact. In this paper, the belt-type system which measures ECG without direct skin-contact is designed and tested. The system consists of developed flexible active electrode (FAE), a driven-right-leg electrode and a module for signal processing and data acqui...

متن کامل

A Data-Driven Compressive Sensing Framework for Long-Term Health Monitoring

Compressive sensing (CS) is a promising technology for realizing energy-efficient wireless sensors for long-term health monitoring. In this paper, we propose a datadriven CS framework that learns signal characteristics and individual variability from patients’ data to significantly enhance CS performance and noise resilience. This is accomplished by a co-training approach that optimizes both th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017