The Cost-Effectiveness of Continuous Glucose Monitoring in Type 1 Diabetes

نویسندگان

  • Elbert S. Huang
  • Michael O'Grady
  • Anirban Basu
  • Aaron Winn
  • Priya John
  • Joyce Lee
  • David Meltzer
  • Craig Kollman
  • Lori Laffel
  • William Tamborlane
  • Stuart Weinzimer
  • Tim Wysocki
چکیده

OBJECTIVE Continuous glucose monitoring (CGM) has been found to improve glucose control in type 1 diabetic patients. We estimated the cost-effectiveness of CGM versus standard glucose monitoring in type 1 diabetes. RESEARCH DESIGN AND METHODS This societal cost-effectiveness analysis (CEA) was conducted in trial populations in which CGM has produced a significant glycemic benefit (A1C >or=7.0% in a cohort of adults aged >or=25 years and A1C <7.0% in a cohort of all ages). Trial data were integrated into a simulation model of type 1 diabetes complications. The main outcome was the cost per quality-adjusted life-year (QALY) gained. RESULTS During the trials, CGM patients experienced an immediate quality-of-life benefit (A1C >or=7.0% cohort: 0.70 quality-adjusted life-weeks [QALWs], P = 0.49; A1C <7.0% cohort: 1.39 QALWs, P = 0.04) and improved glucose control. In the long-term, CEA for the A1C >or=7.0% cohort, CGM was projected to reduce the lifetime probability of microvascular complications; the average gain in QALYs was 0.60. The incremental cost-effectiveness ratio (ICER) was $98,679/QALY (95% CI -60,000 [fourth quadrant] to -87,000 [second quadrant]). For the A1C <7.0% cohort, the average gain in QALYs was 1.11. The ICER was $78,943/QALY (15,000 [first quadrant] to -291,000 [second quadrant]). If the benefit of CGM had been limited to the long-term effects of improved glucose control, the ICER would exceed $700,000/QALY. If test strip use had been two per day with CGM long term the ICER for CGM would improve significantly. CONCLUSIONS Long-term projections indicate that CGM is cost-effective among type 1 diabetic patients at the $100,000/QALY threshold, although considerable uncertainty surrounds these estimates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-effectiveness of continuous glucose monitoring and intensive insulin therapy for type 1 diabetes

BACKGROUND Our objective was to determine the cost-effectiveness of Continuous Glucose Monitoring (CGM) technology with intensive insulin therapy compared to self-monitoring of blood glucose (SMBG) in adults with type 1 diabetes in the United States. METHODS A Markov cohort analysis was used to model the long-term disease progression of 12 different diabetes disease states, using a cycle leng...

متن کامل

Mitigating Severe Hypoglycemia by Initiating Inpatient Continuous Glucose Monitoring for Type 1 Diabetes Mellitus.

 Continuous glucose monitoring for type 1 diabetes mellitus will go forward for refinement as a systematic review. The scope of this topic, including populations, interventions, comparators, and outcomes, will be further developed in the refinement phase.  When key questions have been drafted, they will be posted on the AHRQ Web site and open for public comment. To sign up for notification wh...

متن کامل

Cost-effectiveness of self-monitoring of blood glucose in patients with type 2 diabetes mellitus managed without insulin.

BACKGROUND The benefits of self-monitoring blood glucose levels are unclear in patients with type 2 diabetes mellitus who do not use insulin, but there are considerable costs. We sought to determine the cost effectiveness of self-monitoring for patients with type 2 diabetes not using insulin. METHODS We performed an incremental cost-effectiveness analysis of the self-monitoring of blood gluco...

متن کامل

تأثیر مداخله آموزشی مبتنی بر الگوی مراقبت پیگیر بر خودپایشی قند خون بیماران دیابتی نوع 2

Background and Aim: Appropriate control of blood sugar delays the onset and progression of diabetes mellitus (DM) complications. Nurses have a decisive role in the education of self-care behaviors to diabetic patients, including self-monitoring of blood glucose. The current study aimed at assessing the effect of educational intervention based on continuous care model on self-monitoring of blood...

متن کامل

Evaluation of a continuous glucose monitoring system for home-use conditions.

OBJECTIVE To evaluate the safety and effectiveness of the FreeStyle Navigator Continuous Glucose Monitoring System when used by adult patients with type 1 or 2 diabetes requiring insulin in the home environment. RESEARCH DESIGN AND METHODS Multicenter, prospective study enrolling 137 subjects. This was a two-phase study consisting of 20 days of use ("masked period") without access to continuo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2010