Fast Automated Liver Delineation from Computational Tomography Angiography

نویسندگان

  • Xiaowei Ding
  • Xin Geng
  • Chenfanfu Jiang
  • Feng Tian
  • Xingjian Yan
  • Hang Qi
  • Lei Zhang
  • Yongchang Zheng
چکیده

Accurate liver segmentation is essential for surgery planning and diagnosis of liver abnormality with algorithms. We propose and validate a multi-atlas segmentation approach with local decision fusion for fast automated liver (with/without abnormality) segmentation on computational tomography angiography (CTA). Thirty-five patients were enrolled in this study. A co-registered segmented CTA atlas is constructed with 20 CTA scans, normal and abnormal subjects with wide range of body-mass index (BMI). Liver segmentation candidates are achieved by a multi-atlas registration algorithm which propagates the segmentation label on each atlas image to the test image by image registration. The final segmentation result is calculated by applying local decision fusion weights to each propagated candidate segmentation. We applied our algorithm on the rest 15 patients and compared them with manual segmentation by two expert readers. Voxel overlap by Dice coefficient between the algorithm and expert readers was 0.93 (range 0.89 0.94). The mean surface distance and Hausdorff distance in millimeters between manually drawn contours and the automatically obtained contours were 1.1 ± 0.9 mm and 5.9 ± 1.7 mm respectively. Using our approach, physicians can accurately segment liver from CTA without tedious manual tracing. Our automated algorithm for liver segmentation achieved accurate segmentation with/without abnormality. c © 2016 The Authors. Published by Elsevier B.V. Peer-review under responsibility of the Organizing Committee of MIUA 2016.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated choroidal neovascularization detection algorithm for optical coherence tomography angiography.

Optical coherence tomography angiography has recently been used to visualize choroidal neovascularization (CNV) in participants with age-related macular degeneration. Identification and quantification of CNV area is important clinically for disease assessment. An automated algorithm for CNV area detection is presented in this article. It relies on denoising and a saliency detection model to ove...

متن کامل

Development and Validation of Intracranial Thrombus Segmentation on CT Angiography in Patients with Acute Ischemic Stroke

BACKGROUND AND PURPOSE Thrombus characterization is increasingly considered important in predicting treatment success for patients with acute ischemic stroke. The lack of intensity contrast between thrombus and surrounding tissue in CT images makes manual delineation a difficult and time consuming task. Our aim was to develop an automated method for thrombus measurement on CT angiography and va...

متن کامل

A Semi-Automated Technique Determining the Liver Standardized Uptake Value Reference for Tumor Delineation in FDG PET-CT

BACKGROUND 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)-computed tomography (CT) has been an essential modality in oncology. We propose a semi-automated algorithm to objectively determine liver standardized uptake value (SUV), which is used as a threshold for tumor delineation. METHODS A large spherical volume of interest (VOI) was placed manually to roughly enclose the rig...

متن کامل

Validation of simplified dosimetry approaches in ⁸⁹Zr-PET/CT: the use of manual versus semi-automatic delineation methods to estimate organ absorbed doses.

PURPOSE Increasing interest in immuno-positron emission tomography (PET) studies requires development of dosimetry methods which will provide accurate estimations of organ absorbed doses. The purpose of this study is to develop and validate simplified dosimetry approaches for (89)Zirconium-PET (Zr-PET)/computed tomography (CT) studies. METHODS Five patients with advanced colorectal cancer rec...

متن کامل

Semi-automated carotid lumen segmentation in computed tomography angiography images.

Carotid artery stenosis causes narrowing of carotid lumens and may lead to brain infarction. The purpose of this study was to develop a semi-automated method of segmenting vessel walls, surrounding tissues, and more importantly, the carotid artery lumen by contrast computed tomography angiography (CTA) images and to define the severity of stenosis and present a three-dimensional model of the ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016