Accurate determination and correction of the lattice parameter of LaB 6 ( standard reference material 660 ) relative to that of Si ( 640 b )

نویسنده

  • C. Q. Tran
چکیده

X-ray powder diffraction and synchrotron radiation have been used to determine the lattice parameter of the NIST standard reference material (SRM 660) LaB6 as 4.156468 Åwith an accuracy of 12 parts per million (p.p.m.), calibrated relative to the lattice parameter of the Si powder standard [a0 = 5.430940 (11) Å, Si 640b]. A discrepancy of 0.00048 (5) Å, or nine standard deviations from the NISTreference, is observed between the currently accepted lattice spacing of LaB6 and the measured value. Twelve different measurements of the lattice parameter were made at beam energies between 10 and 20 keV. The observed discrepancy in the lattice parameter is consistent for the different energies used. The absolute values of the mean difference between the measured and calculated 2! centroids, "2! j j, are highly consistent, between 0.0002 and 0.0004! for energies from 5 to 14 keV, and between 0.0005 and 0.0008! for energies from 15 to 20 keV. In order to determine the peak positions with high precision, account must be taken of the observed peak asymmetry. It is shown that significant asymmetry is due to peak broadening and must be taken into account in order to determine accurate peak locations and lattice spacings. The approach shows significant advantages over conventional analysis. The analysis of peak broadening is compared with models used in Rietveld analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Determination of Full Energy Peak Efficiency for HPGe Detector and Self-Absorption Correction of Environmental Samples

The Monte Carlo method was used to determine full energy efficiency of a high-purity germanium (HPGe) coaxial detector within an energy range of 53.2-2614 keV. Also, measurement was carried out for a standard Marinelli beaker of 600cm3, which was placed into the reference material of mixed gamma. The plot of the experimentally derived effic...

متن کامل

Promotion of the Cupellation Method for Accurate Determination of Gold Alloy’s Karat Containing Platinum-Group Metals

The main standard method for gold karat determination is the cupellation method. However, this method is not sufficiently accurate to determine gold karat in the presence of insoluble Platinum–Group Metals (PGMs), such as Ir, Ru, and Rh. In this study, for the first time, a complementary method that can be used coupled with the reference cupellation method is presented for the high...

متن کامل

Determination of optimized sediment rating equation and its relationship with physical characteristics of watershed in semiarid regions: A case study of Pol-Doab watershed, Iran

Managers always consider the precise estimation of sediments in watersheds due to various conditions, such assoil and water resources management, construction, infrastructure and economical and social issues. In this condition,an optimized determination of sediment rating equation (typical method until now for sediment yield estimation) isessential to investigate sediment yield in rivers. In th...

متن کامل

Application of Network RTK Positions and Geometric Constraints to the Problem of Attitude Determination Using the GPS Carrier Phase Measurements

Nowadays, navigation is an unavoidable fact in military and civil aerial transportations. The Global Positioning System (GPS) is commonly used for computing the orientation or attitude of a moving platform. The relative positions of the GPS antennas are computed using the GPS code and/or phase measurements. To achieve a precise attitude determination, Carrier phase observations of GPS requiring...

متن کامل

Least-squares support vector machine and its application in the simultaneous quantitative spectrophotometric determination of pharmaceutical ternary mixture

This paper proposes the least-squares support vector machine (LS-SVM) as an intelligent method applied on absorption spectra for the simultaneous determination of paracetamol (PCT), caffeine (CAF) and ibuprofen (IB) in Novafen. The signal to noise ratio (S/N) increased. Also, In the LS - SVM model, Kernel parameter (σ2) and capacity factor (C) were optimized. Excellent prediction was shown usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009