Location accuracy limitations for CCD cameras
نویسنده
چکیده
The accurate measurement of the position of celestial objects is a fundamental step for several astrophysical investigations. For ground based instruments, the atmosphere is considered the basic limiting factor; in space, the knowledge of the instrumental parameters and/or of their stability define the performance limits, but CCD cameras operated in time delay integration may take advantage of their operating mode to reduce significantly the calibration problem. We implemented a low-cost laboratory experiment aimed at assessing the precision achievable in the location determination with a CCD camera, by evaluating the measurement repeatability throughout a set of images of a simulated stellar field. Our experiment provides an initial location dispersion of the order of 1/100 of the CCD pixel, with clear evidence of dominant common mode effects. After removing such terms with straightforward numerical procedures, we achieve a final location precision of 1/700 pixel on individual images, or 1/1300 pixel on co-added images. The scaling of precision with target magnitude is in quite good agreement with theoretical expectations. The initial common mode systematics appear to be induced by the thermal control of the CCD camera head, which degrades the structural stability. In actual implementations, such problems can be greatly reduced by proper design. Finally, our results show that residual effects, which could hamper the final astrometric accuracy, can be calibrated out with simple procedures.
منابع مشابه
Comparative Geometric Tests of Industrial and Scientific Ccd Cameras Using Plumb Line and Test Range Calibrations
Small format, medium resolution CCD cameras are at present widely used for industrial metrology applications. Large format, high resolution CCD cameras are principally used for scientific applications, but are slowly infiltrating photogrammetry and dramatically improving the object space accuracy achievable by close range measurement. The calibration of all types of CCD cameras is necessary in ...
متن کاملThe perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs
Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...
متن کاملDefocusing Effect Studies in MTF of CCD Cameras Based on PSF Measuring Technique
Defocusing effects in modulation transfer function (MTF) measurement of charge coupled device (CCD) cameras is the main focus of current paper. We introduce measuring Point-spread function (PSF) in order to calculate the MTF and further more we will study the shape of MTF and its cut-off frequency by adjusting the lens focusing in different locations. A collimated white light LED by broadband s...
متن کاملStroboscope Based Synchronization of Full Frame CCD Sensors
The key obstacle to the use of consumer cameras in computer vision and computer graphics applications is the lack of synchronization hardware. We present a stroboscope based synchronization approach for the charge-coupled device (CCD) consumer cameras. The synchronization is realized by first aligning the frames from different video sequences based on the smear dots of the stroboscope, and then...
متن کاملClose Range Photogrammetric Network Design for Panoramic Cameras by Heuristic Simulation
Linear array CCD-based panoramic cameras are being used also in measurement applications. The elegant image acquisition mode and the high information content of those images make them suitable candidates for quantitative image analysis. The best possible accuracy is acquired by a suitable sensor model and following the concept of network design. In our previous investigations we designed a sens...
متن کامل