Automatic calculation and visualization of nuclear density in whole slide images of hepatic histological sections.
نویسندگان
چکیده
An automatic method for estimating the density of cell nuclei in whole slide images (WSI's) of hepatic histological sections is presented. The method can be applied to hematoxylin-eosin (H&E) stained sections with slight histological atypism, such as early well-differentiated hepatocellular carcinoma (ewHCC). It is shown that measured nuclear density is affected by the nuclear size due to fragments of nuclei. This size-dependent problem has been solved by estimating the standard nuclear area for each image patch. The method extracts typical nuclei, which are used to automatically adjust the parameters, including the standard nuclear area. The method is robust for variations in contrast, color, and nuclear size. 40 image patches sampled from 20 WSI's of surgical sections were used for accuracy evaluation. The mean absolute percentage error of estimated nuclear densities was 8.2%. It was also confirmed that the distributions of nuclear density were successfully estimated and visualized for all 20 WSI's. The computation time for a WSI of typical surgical section (754 mm2, about 1,280,000 nuclei) was about 57 minutes on a PC.
منابع مشابه
A CAD System Framework for the Automatic Diagnosis and Annotation of Histological and Bone Marrow Images
Due to ever increasing of medical images data in the world’s medical centers and recent developments in hardware and technology of medical imaging, necessity of medical data software analysis is needed. Equipping medical science with intelligent tools in diagnosis and treatment of illnesses has resulted in reduction of physicians’ errors and physical and financial damages. In this article we pr...
متن کاملBuilding of a composite virtual slide from contiguous tissue samples
BACKGROUND Currently available microscope slide scanners produce whole slide images at various resolutions from histological sections. Nevertheless, acquisition area and so visualization of large tissue samples are limited by the standardized size of glass slides, used daily in pathology departments. The proposed solution has been developed to build composite virtual slides from images of large...
متن کاملFeasibility of using statistical tests in evaluation of non-uniformity [Persian]
Introduction: Non-uniformity test is essentially the only required daily QC procedure in nuclear medicine practice. Noise creates statistical variation or random error in a flood image. Non-uniformity on the other hand does not have statistical nature and may be regarded as systemic error. The present methods of non-uniformity calculation do not distinguish between these two types of erro...
متن کاملF-18 FDG PET/CT imaging of primary hepatic neuroendocrine tumor
Primary hepatic neuroendocrine tumors (PHNETs) are extremely rare neoplasms. Herein, we report a case of a 70-year-old man with a hepatic mass. The non-contrast computed tomography (CT) image showed a low-density mass, and dynamic CT images indicated the enhancement of the mass in the arterial phase and early washout in the late phase. F18- fluorodeoxyglucose (18F-FDG) positron emission tomogra...
متن کاملCalculation of nuclear level density parameter as a function of tmperature and mass number
Nuclear level density is one of the most important concepts in nuclear physics; basically, it is the key in dealing with nuclear statistical problems. This quantity plays an essential role in the statistical calculation of reactor physics, astrophysics, researches in the average energy of heavy- ion collision and calculations related to neutron evaporation and other applications. This quantity ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Bio-medical materials and engineering
دوره 26 Suppl 1 شماره
صفحات -
تاریخ انتشار 2015