Is the distal radioulnar variance useful for identification of radial head prosthesis overlengthening? A cadaver study

نویسندگان

  • Kilian Wegmann
  • Wei Zhang
  • Volker Strauss
  • Christian Ries
  • Lars P. Müller
  • Klaus J. Burkhart
چکیده

BACKGROUND Overlengthening by radial head prosthetic replacement leads to insufficient functionality and increased capitellar wear. It has been shown that in monopolar prostheses, the radial overlengthening by an overstuffed prosthesis leads to significant differences in the distal radioulnar variance at the wrist. This study evaluated ipsilateral ulnar variance as a predictor for overlengthening after implantation of a multipolar prosthesis. METHODS The radial heads of seven fresh frozen upper extremities were resected and a multipolar radial head prosthesis was implanted. Thereafter, the native radioulnar variance at the wrist was documented via fluoroscopy. The alignment of the distal radioulnar joint in neutral, pronated and supinated rotational positions of the forearm was recorded fluoroscopically, and digital image analysis was performed regarding radioulnar shifting. RESULTS Statistical analysis of the difference between native height and the manipulated states did not show consistent significant differences with stepwise overlengthening of +1.5, +3, +4.5 and +6 mm and with respect to rotational position of the forearm (p > 0.05). Interclass correlation coefficients showed excellent interobserver reliability (ICC 96%), as did tests for intraobserver reliability (ICC 98-99%). CONCLUSIONS No consistent influence of overlengthening on the alignment of the radius and ulna at the distal radioulnar joint was found after sequential overlengthening with a multipolar prosthesis. Maybe the ligamentous structures of the forearm prevent significant longitudinal dislocation of the radius, as the multipolar prosthesis gives way by at the radiocapitellar joint. According to the data of the present study, the ipsilateral wrist is not useful in diagnosing overlengthening of the radial column in multipolar prosthetic replacement of the radial head-in contrast to the reported results with monopolar prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcome Assessment after Aptis Distal Radioulnar Joint (DRUJ) Implant Arthroplasty

Background:  Conventional treatments after complicated injuries of the distal radioulnar joint (DRUJ) such as Darrach and Kapandji-Sauvé procedures have many drawbacks, which may eventually lead to a painful unstable distal ulna.  The development of DRUJ prosthesis has significantly evolved over the past years. In this study, we assessed the outcome results of patients after DRUJ implant arthro...

متن کامل

Defining residual radial translation of distal radius fractures: a potential cause of distal radioulnar joint instability.

BACKGROUND Instability of the distal radioulnar joint (DRUJ) is a complication that can occur following distal radius fracture or malunion. We have observed that residual radial translation of the distal radius, relative to the radial shaft, may be a causal factor of DRUJ instability, even once the traditional radiographic parameters (volar tilt, radial inclination, and ulnar variance) have bee...

متن کامل

Radial Head Prosthesis Removal:a Retrospective Case Series of 14 Patients

Background:  The purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis.   Methods:  This is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. The average time between implantation and removal was 23 month...

متن کامل

Effect of Triangular Ligament Tears on the Distal Radioulnar Joint Instability and the Evaluation of 3 Clinical Tests: A Biomechanical Study

INTRODUCTION: The purpose of this cadaver study was to evaluate the effect of triangular ligament tears on distal radio-ulnar joint instability by motion analysis. The amount of the distal radius displacement against the ulnar head was measured during passive wrist motion to simulate daily activities of the hands, and three clinical tests for the evaluation of distal radio-ulnar joint instabili...

متن کامل

Computer-aided analysis of radial head morphometry.

Operative treatment of displaced and comminuted radial head fractures involves internal fixation with plates and screws in cases where reconstruction is possible and replacement with a radial head prosthesis when comminution renders the radial head unreconstructable. The purposes of this study were to evaluate the morphometry of the radial head using a modern technique and to compare the findin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2016