Stroke volume variation (SVV) and pulse pressure variation (PPV) as indicators of fluid responsiveness in sevoflurane anesthetized mechanically ventilated euvolemic dogs
نویسندگان
چکیده
Changes in stroke volume variation (SVV) and pulse pressure variation (PPV) in response to fluid infusion were experimentally evaluated during vecuronium infusion and sevoflurane anesthesia in 5 adult, mechanically ventilated, euvolemic, beagle dogs. Sequential increases in central venous pressure (CVP; 3-7[baseline], 8-12, 13-17, 18-22 and 23-27 mmHg) were produced by infusing lactated Ringer's solution and 6% hydroxyethyl starch solution. Heart rate (beats/min), right atrial pressure (RAP, mmHg), pulmonary arterial pressure (PAP, mmHg), pulmonary capillary wedge pressure (PCWP, mmHg), transpulmonary thermodilution cardiac output (TPTDCO, l/min), stroke volume (SV, ml/beat), arterial blood pressure (ABP, mmHg), extravascular lung water (EVLW, ml), pulmonary vascular permeability index (PVPI, calculated), SVV (%), PPV (%) and systemic vascular resistance (SVR, dynes/sec/cm5) were determined at each predetermined CVP range. Heart rate (P=0.019), RAP (P<0.001), PAP (P<0.001), PCWP (P<0.001), TPTDCO (P=0.009) and SV (P=0.04) increased and SVR (P<0.001), SVV (P<0.001) and PPV (P<0.001) decreased associated with each stepwise increase in CVP. Arterial blood pressure, EVLW, PVPI and the arterial partial pressures of oxygen and carbon dioxide did not change. The changes in SVV and PPV directly reflected the fluid load and the minimum threshold values for detecting fluid responsiveness were SVV ≥11% and PPV ≥7% in dogs.
منابع مشابه
Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy
BACKGROUND During carotid endarterectomy (CEA), hemodynamic stability and adequate fluid management are crucial to prevent perioperative cerebral stroke, myocardial infarction and hyperperfusion syndrome. Both pulse pressure variation (PPV) and stroke volume variation (SVV), dynamic preload indices derived from the arterial waveform, are increasingly advocated as predictors of fluid responsiven...
متن کاملAutomated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery.
BACKGROUND Off-line calculation of the pulse pressure variation (PPV(ref)) has repeatedly been shown to be a reliable predictor of fluid responsiveness in mechanically ventilated patients. This study was designed to assess the ability of two algorithms for automated calculation of PPV (PPV(auto)) (Intellivue MP 70) and stroke volume variation (SVV(auto)) (FloTrac/Vigileo) to predict fluid respo...
متن کاملUsing pulse pressure variation or stroke volume variation to diagnose right ventricular failure?
pulse pressure variation (PPV) is not an accurate predictor of fl uid responsiveness in subjects with pulmonary hypertension [1,2]. We agree that PPV and stroke volume variation (SVV) may not work in patients with right ventricular (RV) failure. Indeed, when PPV and SVV are related to an inspiratory increase in RV afterload (and not to a decrease in RV preload), they cannot serve as indicators ...
متن کاملComparison of stroke volume variation with pulse pressure variation as a diagnostic indicator of fluid responsiveness in mechanically ventilated critically ill patients.
OBJECTIVE To compare the diagnostic accuracy of stroke volume variation (SVV) and pulse pressure variation (PPV) in studies that examined both parameters in the same patient population. METHODS Literature search was conducted in PubMed, EMBASE, CINAHL, and Google Scholar. Receiver operator characteristic (ROC) curves were examined, and summary ROC curves were plotted. RESULTS The study was ...
متن کاملUncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation.
BACKGROUND Stroke volume variation (SVV) is able to predict adequately the individual response to fluid loading. Our objective was to assess whether the SVV measured by a new algorithm (Vigileo; Flotrac) can predict fluid responsiveness. METHODS Forty mechanically ventilated patients undergoing liver transplantation, who needed volume expansion (VE), were included. VE was done with albumin (4...