Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

نویسندگان

  • M L Wilson
  • M P Weinstein
  • L G Reimer
  • S Mirrett
  • L B Reller
چکیده

In a collaborative study at three university hospitals, the recovery of microorganisms and the speed of detection of microbial growth by the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) and BACTEC 660/730 (Becton-Dickinson Diagnostic Instrument Systems, Sparks, Md.) nonradiometric blood culture systems were compared. A total of 5,918 comparisons were made between BacT/Alert aerobic and BACTEC NR 6A bottles and 5,992 comparisons were made between BacT/Alert anaerobic and BACTEC NR 7A bottles. Each bottle was inoculated with 5 ml of blood. The overall recoveries of microorganisms from the two aerobic bottles were comparable; members of the family Enterobacteriaceae were recovered more often from BacT/Alert aerobic bottles alone (P less than 0.001). The overall recoveries of microorganisms from the anaerobic bottles were not significantly different. Growth of Staphylococcus aureus (P less than 0.001), coagulase-negative staphylococci (P less than 0.01), streptococci (P less than 0.001), Escherichia coli (P less than 0.01), other members of the family Enterobacteriaceae (P less than 0.02), and Pseudomonas aeruginosa (P less than 0.05) was detected earlier in BacT/Alert aerobic bottles. Growth of S. aureus (P less than 0.001), coagulase-negative staphylococci (P less than 0.05), enterococci (P less than 0.01), Streptococcus pneumoniae (P less than 0.02), viridans group streptococci (P less than 0.05), E. coli (P less than 0.001), Klebsiella pneumoniae (P less than 0.01), and other members of the family Enterobacteriaceae (P less than 0.001) was detected earlier in BacT/Alert anaerobic bottles. In a system-versus-system comparison, more gram-positive cocci were recovered from the BACTEC system alone (P < 0.05), and more members or the family Enterobacteriaceae were recovered from the BacT/Alert system alone (P < 0.001). As a system, the BacT/Alert system detected growth of S. aureus (P < 0.001), coagulase-negative staphylococci (P < 0.01), streptococci (P < 0.001), E. coli (P < 0.001), other members of the familyEnterobacteriaceae (P < 0.001), and P. aeruginosa (P < 0.05) earlier than the BACTEC system did. Significantly fewer (40 versus 1,183) false-positive results occurred with the BacT/Alert system. We conclude that the BacT/Alert and BACTEC 660/730 nonradiometric systems are comparable for recovering clinically significant microorganisms form adult patients with bacteremia or fungemia, but that the BacT/Alert system detects microbial growth earlier than the BACTEC system does, with significantly fewer false-positive results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.

A 20-ml blood sample was collected from adult patients with suspected bloodstream infections and distributed equally into the four volume-controlled bottles of a blood culture set consisting of aerobic and anaerobic BACTEC Plus/F bottles and aerobic and anaerobic BacT/Alert FAN bottles. All bottles were incubated in their respective instruments for a standard 5-day protocol or until the instrum...

متن کامل

Comparison of the Bactec 9240 and BacT/Alert blood culture systems for evaluation of placental cord blood for transfusion in neonates.

The Bactec 9240 and the BacT/Alert blood culture systems were compared as a means for detection of bacterial contaminants in whole blood, concentrated red cells, and plasma preparations prepared from umbilical cord blood (UCB) samples. Ninety-two UCB units seeded with low levels of various bacteria were evaluated. In more than 50% of cases, growth was not detected in plasma using either system ...

متن کامل

Controlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia.

To compare the performance of the BACTEC 13A (Becton Dickinson, Sparks, Md.), BACTEC MYCO/F LYTIC (Becton Dickinson), BacT/ALERT MB (bioMérieux, Durham, N.C.), and ISOLATOR 10 lysis-centrifugation (Wampole Laboratories, Cranbury, N.J.) systems for detection of mycobacteremia in adults, we inoculated 5-ml aliquots of blood from patients with suspected mycobacteremia into the bottle or tube requi...

متن کامل

Comparison of BACTEC PLUS blood culture media to BacT/Alert FA blood culture media for detection of bacterial pathogens in samples containing therapeutic levels of antibiotics.

Blood culture bottles with antimicrobial removal systems are recommended for patients who develop fever while on antibiotics. This study compared the ability of Becton Dickinson (Sparks, MD) BACTEC PLUS bottles and bioMerieux (Durham, NC) BacT/Alert FA bottles to effectively remove vancomycin, cefoxitin, ceftriaxone, cefepime, piperacillin-tazobactam, ampicillin, oxacillin, gentamicin, and a co...

متن کامل

Clinical comparison of isolator and BACTEC 660 resin media for blood culture.

The 10-ml Isolator system (E.I. du Pont de Nemours & Co., Inc., Wilmington, Del.) was compared with the BACTEC 16A-17A nonradiometric resin system (Johnston Laboratories, Inc., Towson, Md.) for isolation of organisms from 6,839 paired blood cultures. Equal volumes of blood (6 to 10 ml for each Isolator and 3 to 5 ml for each BACTEC bottle) were cultured in parallel in the two systems, and 600 i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 1992