Hemodynamic analysis of brain death patients using pulse-induced contour cardiac output (PiCCO)

نویسندگان

  • Jian-Ying Guo
  • Ming-Xing Fang
  • Qing-Sheng Huang
  • Hua-Wei Zhang
  • Li-Xia Zhang
  • Zhi-Yong Wang
چکیده

The aim of this study is to investigate the hemodynamic characteristics of brain death patients via PulseInduced Contour Cardiac Output (PiCCO). 20 brain-death patients were included in the test group, and 20 with GCS ≥ 8 were included in the control group. The hemodynamic characteristics Pre-load (ITBVI/ EVLWI), Cardiac Pump Function: (CI/SI/GEF/CFI/dPmax), Post-load: (SVRI) were collected by PiCCO at 0, 6, 12, 24 and 48 h were compared between 2 groups, dopamine and pituitary hormone can be used in some unstable patients in the test group. The preload ITBVI in test group at 0 h was lower than the control group (P<0.05), but no difference after volume management at 6 h. After volume management, the result of post-load SVRI in the test group decreased significantly compared with the control group (P<0.01); there were no significant differences of the results of HR, CI and SI between two group, but the results of GEF, CFI and dPmax decreased in the test group (P<0.01), which indicated the decrease of contractive force of cardic. Unstable hemodynamic was common in brain-death patients, with the decrease of the pre-load, post-load and contractive force of cardic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Failure of continuous cardiac output measurement using the PiCCO Device during induced hypothermia: a case report.

Continuous cardiac output measurement using pulse contour analysis is a technique gaining widespread acceptance in intensive care units. We report a case where a pulse contour analysis computer (PiCCO, Pulsion Medical Systems, Munich, Germany) failed to calibrate in a patient who was undergoing induced hypothermia for anoxic brain injury. Despite several attempts to calibrate, using increased c...

متن کامل

Lack of agreement between esophageal doppler cardiac output measurements and continuous pulse contour analysis during off-pump cardiac surgery

Objective: Transesophageal echo-Doppler cardiac output as well as arterial pulse contour analyses cardiac output are increasingly used for cardiac output monitoring. No data are available whether both techniques may be used interchangeably in patients undergoing cardiac surgery. Design: Prospective, observational study Setting: Operating rooms of a university affiliated hospital. Patients: 30 p...

متن کامل

Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers

INTRODUCTION This study was designed to test the hypothesis of equivalence in cardiac output (CO) and stroke volume (SV) monitoring capabilities of two devices: non invasive transthoracic bioreactance (NICOM), and a pulse contour analysis (PICCO PC) coupled to transpulmonary thermodilution (PICCO TD). METHODS We included consecutive patients of a single ICU following cardiac surgery. Continuo...

متن کامل

Pulse contour analysis: Is it able to reliably detect changes in cardiac output in the haemodynamically unstable patient?

Three pulse contour systems for monitoring cardiac output - LiDCO Plus™, PiCCO Plus™ and FloTrac™ - were compared in postcardiac surgery patients. None of the three methods demonstrated good trending ability according to concordance analysis. Pulse contour systems remain unreliable in the haemodynamically unstable patient.

متن کامل

Cardiac output measurement using a modified carbon dioxide Fick method: comparison analysis with pulmonary artery catheter method and pulse induced contour cardiac output method.

OBJECTIVES In the present study, cardiac output in mechanically ventilated patients were determined using three methods including modified CO2-Fick (mCO2F), pulmonary artery catheter (PAC), and pulse induced contour cardiac output (PiCCO) methods and the results were compared to assess the effectiveness of mCO2F method in measuring the cardiac output. METHOD Mechanically ventilated and hemody...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017