Evaluation of medical devices in thoracic radiograms in intensive care unit - time to pay attention!

نویسندگان

  • Ana Sofia Linhares Moreira
  • Maria da Graça Alves Afonso
  • Mónica Ribeiro dos Santos Alves Dinis
  • Maria Cristina Granja Teixeira dos Santos
چکیده

OBJECTIVE To identify and evaluate the correct positioning of the most commonly used medical devices as visualized in thoracic radiograms of patients in the intensive care unit of our center. METHODS A literature search was conducted for the criteria used to evaluate the correct positioning of medical devices on thoracic radiograms. All the thoracic radiograms performed in the intensive care unit of our center over an 18-month period were analyzed. All admissions in which at least one thoracic radiogram was performed in the intensive care unit and in which at least one medical device was identifiable in the thoracic radiogram were included. One radiogram per admission was selected for analysis. The radiograms were evaluated by an independent observer. RESULTS Out of the 2,312 thoracic radiograms analyzed, 568 were included in this study. Several medical devices were identified, including monitoring leads, endotracheal and tracheostomy tubes, central venous catheters, pacemakers and prosthetic cardiac valves. Of the central venous catheters that were identified, 33.6% of the subclavian and 23.8% of the jugular were malpositioned. Of the endotracheal tubes, 19.9% were malpositioned, while all the tracheostomy tubes were correctly positioned. CONCLUSION Malpositioning of central venous catheters and endotracheal tubes is frequently identified in radiograms of patients in an intensive care unit. This is relevant because malpositioned devices may be related to adverse events. In future studies, an association between malpositioning and adverse events should be investigated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Support Program on Satisfaction of Family Members of ICU Patients

Background: This study has been conducted to investigate the effect of family-centered support program on satisfaction of the family members of patients in intensive care unit. Hospitalization of patient in intensive care unit causes crisis in family. It is very important to pay attention to the role of patient’s family in support and care of patients in intensive care unit, to pay attent...

متن کامل

The Correlation between Attachment Behaviors and Fear Of COVID-19 in Mothers with Neonates Admitted to the Neonatal Intensive Care Unit in Hospitals Under the Supervision of Iran University of Medical Sciences in the Covid-19 Pandemic 2021

Background and Aim: Infant hospitalization in the Neonatal Intensive Care Unit (NICU) causes loss or delay in maternal and infant attachment. On the other hand, quarantine and the limits of social distancing during the Covid 19 virus epidemic have psychological consequences, including an increased fear of Covid 19 infection. The aim of this study was to determine the relationship between attach...

متن کامل

COMPARISON OF INCIDENCE AND GRADE OF PRESSURE ULCER IN SMOKERS AND NON-SMOKERS ADMITTED TO INTENSIVE CARE UNIT

Background & Aims: Pressure ulcer is a serious problem in patients admitted to the intensive care unit. It is associated with major complications such as prolonged length of stay and delayed recovery. The aim of this study was to compare the incidence and grade of pressure ulcers in smokers and non-smokers admitted to the intensive care unit. Materials & Methods: This study is an analytical cr...

متن کامل

Determination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward

Background: In Neonatal intensive care units (NICU) different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the inte...

متن کامل

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2016