Virtual lymph node analysis to evaluate axillary lymph node coverage provided by tangential breast irradiation

نویسندگان

  • Shin-Hyung Park
  • Jae-Chul Kim
  • Jeong Eun Lee
  • In-Kyu Park
چکیده

PURPOSE To investigate the coverage of axillary lymph node with tangential breast irradiation fields by using virtual lymph node (LN) analysis. MATERIALS AND METHODS Forty-eight women who were treated with whole breast irradiation after breast-conserving surgery were analyzed. The axillary and breast volumes were delineated according to the Radiation Therapy Oncology Group (RTOG) contouring atlas. To generate virtual LN contours, preoperative fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scans with identifiable LN were fused with the CT scans, and the virtual LN contour were delineated on the CT. RESULTS The median level I and II axillary volume coverage percentages at the VD95% line were 33.5% (range, 5.3% to 90.4%) and 0.6% (range, 0.0% to 14.6%), respectively. Thirty-one LNs in 18 patients were delineated (26 in level I and 5 in level II). In the level I axilla, 84.6% of virtual LNs were encompassed by the 95% isodose line. In the level II axilla, by contrast, none of the virtual LNs were encompassed by the 95% isodose volumes. There was a substantial discrepancy between the RTOG contouring atlas-based axillary volume analysis and the virtual LN analysis, especially for the level I axillary coverage. The axillary volume coverage was associated with the body mass index (BMI) and breast volume. CONCLUSION The tangential breast irradiation did not deliver adequate therapeutic doses to the axillary region, particularly those in the level II axilla. Patients with small breast volumes or lower BMI showed reduced axillary coverage from the tangential breast fields. For axillary LN irradiation, individualized anatomy-based radiation fields for patients would be necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardization of whole breast radiotherapy is required for safe omission of axillary lymph node dissection in breast cancer patients

Background: The purpose of this study was to assess the dose distribution and coverage of level Ⅰ-Ⅱ axillary lymph nodes during whole breast tangential field radiotherapy (RT) after breast-conserving surgery in patients with breast cancer. Materials and Methods: The level Ⅰ-Ⅱ axillary lymph node volumes were retrospectively contoured by a single radiation oncologist based on computed tomography...

متن کامل

Axillary irradiation in breast cancer; does meticulous contouring make a difference?

Background: Due to the current trends towards replacing axillary dissection with radiotherapy, the need for more precise definition for different nodal stations becomes a must to ensure safe and adequate dose coverage. So, our study aimed to evaluate the coverage of axillary nodal volumes based on Project on Cancer of the Breast (PROCAB) guidelines, for cases previously treated with our standar...

متن کامل

Prediction Axillary Lymph Node Involvement Status on Breast Cancer Data

Introduction: one of the foremost usual methods for evaluating breast cancer is the removal of axillary lymph nodes (ALN) which include complications such as edema, limited hand movements, and lymph accumulation. Although studies have shown that the sentinel gland condition represents the axillary nodules context in the mammary gland, the efficacy, and safety of the guard node biopsy need to be...

متن کامل

Dose coverage of axillary level I-III areas during whole breast irradiation with simplified intensity modulated radiation therapy in early stage breast cancer patients

PURPOSE This study was designed to evaluate the dose coverage of axillary areas during whole breast irradiation with simplified intensity modulated radiation therapy (s-IMRT) and field-in-field IMRT (for-IMRT) in early stage breast cancer patients. METHODS Sixty-one consecutive patients with breast-conserving surgery and sentinel lymph node biopsy were collected. Two plans were created for ea...

متن کامل

Irradiation with standard tangential breast fields in patients treated with conservative surgery and sentinel node biopsy: using a three-dimensional tool to evaluate the first level coverage of the axillary nodes.

Recent data show that axillary coverage can be obtained, but only through a selective CT-based treatment planning, as standard tangential fields are inadequate to deliver therapeutic doses. Currently, the replacement of axillary dissection with new techniques, such as sentinel node (SN) biopsy, makes it necessary to re-address the question about the real role of axillary irradiation, complicate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2015