Monitoring depth of anesthesia utilizing a combination of electroencephalographic and standard measures.

نویسندگان

  • Gerhard Schneider
  • Denis Jordan
  • Gerhard Schwarz
  • Petra Bischoff
  • Cornelis J Kalkman
  • Hermann Kuppe
  • Ingrid Rundshagen
  • Adem Omerovic
  • Matthias Kreuzer
  • Gudrun Stockmanns
  • Eberhard F Kochs
چکیده

BACKGROUND For decades, monitoring depth of anesthesia was mainly based on unspecific effects of anesthetics, for example, blood pressure, heart rate, or drug concentrations. Today, electroencephalogram-based monitors promise a more specific assessment of the brain function. To date, most approaches were focused on a "head-to-head" comparison of either electroencephalogram- or standard parameter-based monitoring. In the current study, a multimodal indicator based on a combination of both electro encephalographic and standard anesthesia monitoring parameters is defined for quantification of "anesthesia depth." METHODS Two hundred sixty-three adult patients from six European centers undergoing surgery with general anesthesia were assigned to 1 of 10 anesthetic combinations according to standards of the enrolling hospital. The anesthesia multimodal index of consciousness was developed using a data-driven approach, which maps standard monitoring and electroencephalographic parameters into an output indicator that separates different levels of anesthesia from awake to electroencephalographic burst suppression. Obtained results were compared with either a combination of standard monitoring parameters or the electroencephalogram-based bispectral index. RESULTS The anesthesia multimodal index of consciousness showed prediction probability (P(K)) of 0.96 (95% CI, 0.95 to 0.97) to separate different levels of anesthesia (wakefulness to burst suppression), whereas the bispectral index had significantly lower PK of 0.80 (0.76 to 0.81) at corrected threshold P value of less than 0.05. At the transition between consciousness and unconsciousness, anesthesia multimodal index of consciousness yielded a PK of 0.88 (0.85 to 0.91). CONCLUSION A multimodal integration of both standard monitoring and electroencephalographic parameters may more precisely reflect the level of anesthesia compared with monitoring based on one of these aspects alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring Depth of Anesthesia by Nonlinear Correlation Measures

Background: Monitoring the depth of anesthesia (DOA) takes an important role for anesthetists in order avoiding undesirable reactions such as intraoperative awareness, prolonged recovery and increased risk of postoperative complications.The Central Nervous System (CNS) is the main target of anesthetic drugs, hence EEG signal processing during anesthesia is helpful for monitoring DOA. In order t...

متن کامل

Impact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery

Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...

متن کامل

بررسی ارتباط کنترل عمق بیهوشی و میزان شفافیت فیلد عمل در اعمال جراحی با فیلد محدود (گوش، بینی و سینوس‌ها) در بیمارستان مرادی رفسنجان در سال 1394: یک گزارش کوتاه

Background and Objective: Operation field in surgeries like sinus endoscopy, rhinoplasty, tympanoplasty, and mastoidectomy is limited and difficult to achieve. Bleeding in the field of these surgeries can opaque operation fields and ultimately affect surgery outcome. This study aimed to evaluate the relationship between anesthesia depth and transparency of operation field in the first and secon...

متن کامل

Quantification of epileptiform electroencephalographic activity during sevoflurane mask induction.

BACKGROUND Sevoflurane may induce epileptiform electroencephalographic activity leading to unstable Bispectral Index numbers, underestimating the hypnotic depth of anesthesia. The authors developed a method for the quantification of epileptiform electroencephalographic activity during sevoflurane anesthesia. METHODS Electroencephalographic data from 60 patients under sevoflurane mask inductio...

متن کامل

Accuracy of narcotrend index in monitoring depth of anesthesia in diabetics: a case report.

ARCOTREND index (NI) is based on studies of normal human brain electrical data. It uses an ordinary electrode to collect and analysis brain electrical signals immediately at any position of the head, to display the state of consciousness and depth of anesthesia of patients on the touch screen after automatic analysis and classification, so as to guide dose adjustment of anesthetics. NI may make...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 120 4  شماره 

صفحات  -

تاریخ انتشار 2014